![Acucraft Blaze BL-6-ST Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/acucraft/blaze-bl-6-st/blaze-bl-6-st_installation-and-operators-manual_2844412033.webp)
33
OPERATION GUIDE
Turning gas off to the appliance
Please check with local codes.In the absence of local
codes, use the current National Fuel Gas Code –
ANSI Z223.1 (NFPA 54) or CAN/CGA B149
Installation Code.
OPERATION GUIDE
Follow the instructions below exactly.
Failure to follow this warning may
result in serious injury or loss of life.
Basic Sequence of Operation
Listed below is a sequence of operation when the
fireplace is functioning properly. If you are experi
-
encing problems with the fireplace not operating
normally, see the Troubleshooting section.
1. The fireplace control switch is turned on.
2. Control Board proves and engages fan.
3. Pressure switch sends signal to control board
proving draft.
4. Control board closes AUX output, energizing igni
-
tion control.
5. The pilot spark igniter will discontinue sparking
after flame has been proven.
6. The pilot will then send gas to the burner as well
as
Ignite gas and prove the flame is burning.
7. Operation normal.
Lighting the Ignition System
WARNING
IMPORTANT:
This appliance is equipped with an ignition sys-
tem
which automatically lights the burner.
DO NOT try to light the burner by hand.
Only use your hand to push in or turn gas control.
NEVER use tools. Call a qualified technician.
Force or attempted repair may result in
BL_ST_INSTL_RevB_4.08.19