22
INSTALLATION GUIDE
The stubbed gas line port and electrical pass through
port are located on the side of the unit. The ignition
system must be just outside of the fireplace. Location
not to exceed 5’ length of ignition cable from the burn
-
er itself. Other components may be remotely located.
Please refer to the specific component installation
manuals for the electronic gas valve, intermittent pilot
module, pilot assembly, and transformer supplied with
this fireplace and written by the manufacturer.
- Connect the ignition cable and other wiring to the
valve and direct intermittent pilot module.
NOTE: These illustrations are not to scale and are for
reference only.
Connecting the Gas Valve & Ignition System
IMPORTANT:
All connections and components should be made
and installed by qualified persons only and checked
and tested for leaks prior to wiring of valve module.
Gas supply should be connected as shown below.
*Shut off supplied by other.
Directions for Connecting a Gas Pressure Test Gauge
The gas control valve (shown to the right) has two test ports for testing input (line pressure) and output (manifold) pressure.
Loosen the pressure tap screw on either test port and place a 5/16” i.d. rubber or plastic tube over the tapered test port. Connect
the tube to the test gauge.
WARNING: The pressure tap screw must be tightened after testing to prevent gas leakage.
INLET
OUTLET
INLET
PRESSURE TAP
PRESSURE REGULATOR
ADJUSTMENT
(UNDER CAP SCREW)
WIRING
TERMINALS (3)
OUTLET
PRESSURE TAP
PILOT OUTLET
4-1/16 (104)
1
(25)
1/4 INCH
QUICK-CONNECT
TERMINALS
4 IN. (102) MAX
SWING RADIUS
1 (25)
2-11/16 (69)
1-7/16
(36)
3-15/16
(99)
1/2
(13)
1/2
(13)
PILOT ADJUSTMENT
(UNDER CAP SCREW)
GAS
CONTROL
KNOB
Safety Shut Off Valve
Gas Valve
BL_ST_INSTL_RevB_4.08.19