PROBABLE CAUSE
REMEDY
PROBLEM
No power
Battery is too warm
— red LED blinks on Battery
Let the Battery cool down
Battery is too cold
— below -10°C (14°F)
Let the Battery warm up
Battery not charged
Check Battery, charge when empty
Power Supply not switched on
Activate Power Supply
Too short a press on Power Button
Press for 2 seconds
Emergency Stop engaged
Disengage Emergency Stop
Power LED turns red
Emergency Stop engaged
Disengage Emergency Stop
Problem with Battery or Power Supply
Try another Battery or Power Supply
Error detected in Ascender
Restart: LED Green — OK
LED Red — Contact ActSafe
distributor or ActSafe
Remote control does not connect
Ascender is not switched on
Switch Ascender on
Distance too far
Get closer to Ascender
Signal
interference
Get closer to Ascender
Remote Control from another Ascender
Find correct Remote Control
62
Содержание ACX
Страница 2: ......
Страница 3: ......
Страница 15: ...C ROPE Rope type and preparation C 01 15 ...
Страница 18: ......
Страница 21: ......
Страница 25: ...Top Rigged Basic setup Bottom Rigged Basic Setup Double load 25 ...
Страница 26: ...Pulley Expert use only Pulley Expert use only ACX pulley rigging on a single anchor 26 ...
Страница 42: ......
Страница 59: ...G SERVICE MAINTENANCE Maintenance and cleaning of the Ascender G 01 Troubleshooting guide G 02 59 ...
Страница 64: ......
Страница 65: ...H POWER ASCENDERS WARRANTY TERMS Warranty terms H 01 65 ...
Страница 68: ......
Страница 69: ...I TECHNICAL DATA Technical data 1 01 69 ...
Страница 71: ...Initial delivery A Inspection B Replaced consumables C Usage log D LOGBOOK 71 ...
Страница 77: ...D USAGE LOG Date Signature Comment 77 ...
Страница 78: ...D USAGE LOG Date Signature Comment 78 ...
Страница 79: ...79 ...