
ORANGE
Overheat indication shown when Power Button is pushed
in case of Ascender overheating
BLUE
The Ascender is being operated by the Remote Control
F.02
ASCENDER ACTIVATION
To activate the Ascender check that the Emergency Stop button is pulled
out. Switch the Ascender on by pushing the Power Button for 2 seconds.
The green indicator LED starts blinking and the Ascender performs
a self-test, which will take a few seconds.
The Ascender is ready to use after you hear a distinct clicking within
the Ascender (brake test) and the green LED indicator is lit continuously.
The Ascender will remain on for 4 hours after its last operation.
BLINKING
The Ascender is starting up and perfoming self-test
GREEN
GREEN
The Ascender is on and ready to use
RED
A fault has been detected and the Ascender will not operate.
Restart the Ascender. If the red light remains lit on restart,
check the troubleshooting guide
Note
The Ascender has no standby
function, the Ascender can
only be switched on by pushing
the Power Button.
46
Содержание ACX
Страница 2: ......
Страница 3: ......
Страница 15: ...C ROPE Rope type and preparation C 01 15 ...
Страница 18: ......
Страница 21: ......
Страница 25: ...Top Rigged Basic setup Bottom Rigged Basic Setup Double load 25 ...
Страница 26: ...Pulley Expert use only Pulley Expert use only ACX pulley rigging on a single anchor 26 ...
Страница 42: ......
Страница 59: ...G SERVICE MAINTENANCE Maintenance and cleaning of the Ascender G 01 Troubleshooting guide G 02 59 ...
Страница 64: ......
Страница 65: ...H POWER ASCENDERS WARRANTY TERMS Warranty terms H 01 65 ...
Страница 68: ......
Страница 69: ...I TECHNICAL DATA Technical data 1 01 69 ...
Страница 71: ...Initial delivery A Inspection B Replaced consumables C Usage log D LOGBOOK 71 ...
Страница 77: ...D USAGE LOG Date Signature Comment 77 ...
Страница 78: ...D USAGE LOG Date Signature Comment 78 ...
Страница 79: ...79 ...