i
Ascender Performance
When using the Battery, the
Ascender has a lifting capacity
of up to 200 kg (440 lb) or up to
a distance of 200 m (656 ft).The
distance is dependent on the
lifted load and temperature of the
environment. The optimal operating
temperature range is between
5°C (41°F) and 35°C (95°F). The
maximum temperature range is
from -10°C (14°F) to 40°C (104°F);
the Battery performance will be
greatly affected in these extreme
conditions. See chart opposite
for detailed information.
Battery Capacity
Low temperatures:
The capacity of the Battery is
affected at temperatures below 5°C
(41°F) which will result in an initial
loss of lifting performance (speed)
and will affect the lifting distance. The
Battery will behave as if it wasn’t fully
charged but will warm itself during
the
fi
rst minutes of operation. Lifting
performance is regained but there will
be a loss in distance depending on
the temperature of the environment.
High temperatures:
Battery performance will be affected
by temperatures over 40°C (104°F)
which will result in high internal battery
temperatures and therefore in a reduced
lifting distance. In case of the Battery
overheating the BMS is designed to
shut the Battery off until the Battery
has cooled to operating temperature.
E.02
PERFORMANCE
RECOMMENDATION
Note
In cold environments, maintain
optimal Battery temperature
and performance by keeping
the Battery in the transportation
box as long as possible.
Initial lift speed capacity will be
limited with a cold Battery. It is
only possible to ascend at lower
speeds until the Battery warms
up and normal performance
can be expected.
There is a difference in
performance between old
and new Batteries, all
fi
gures
are based on new Batteries.
36
Содержание ACX
Страница 2: ......
Страница 3: ......
Страница 15: ...C ROPE Rope type and preparation C 01 15 ...
Страница 18: ......
Страница 21: ......
Страница 25: ...Top Rigged Basic setup Bottom Rigged Basic Setup Double load 25 ...
Страница 26: ...Pulley Expert use only Pulley Expert use only ACX pulley rigging on a single anchor 26 ...
Страница 42: ......
Страница 59: ...G SERVICE MAINTENANCE Maintenance and cleaning of the Ascender G 01 Troubleshooting guide G 02 59 ...
Страница 64: ......
Страница 65: ...H POWER ASCENDERS WARRANTY TERMS Warranty terms H 01 65 ...
Страница 68: ......
Страница 69: ...I TECHNICAL DATA Technical data 1 01 69 ...
Страница 71: ...Initial delivery A Inspection B Replaced consumables C Usage log D LOGBOOK 71 ...
Страница 77: ...D USAGE LOG Date Signature Comment 77 ...
Страница 78: ...D USAGE LOG Date Signature Comment 78 ...
Страница 79: ...79 ...