68
Installation and Commissioning Guide 500-700 Tri-Capacity Split Ducted
Doc. No.0525-098
Ver. 2 210330
Installation and Commissioning Guide
Split Tri-Capacity
26.03. 24VAC Relay Output Compressor and 0-10 Analogue Output Indoor Fans
R
Th
is
d
ra
w
in
g r
em
ai
ns
th
e i
nte
lle
ctu
al
p
ro
pe
rty
o
f A
ct
ro
n
E
ngi
ne
er
ing
P
ty
Lt
d.
R
ep
rodu
ct
ion
, m
odi
fic
at
ion
an
d/
or
di
st
rib
ut
ion
ar
e
pr
oh
ib
ited
w
ith
ou
t w
ritte
n c
on
se
nt.
R
ev
is
io
n
0515-
8803-
3
A4
S
ize
:
TR
I-C
A
P
A
C
ITY
D
es
cr
ipt
ion:
B
as
e
M
odel
N
o:
V
ar
iat
ion
C
ode:
24V
A
C
C
O
M
P
&
0-
10V
IN
F
A
N
V
ar
iat
ions
:
A
D
raw
ing
N
o:
D
raw
n:
D
at
e:
03-
09-
20
14
24-
10-
20
14
MH
MJ
H
A
pp
rov
ed:
D
at
e:
R
ev.
D
es
cr
ipt
ion
Da
te
By
P
CR
OR
IGI
N
A
L
A
C
M
10
0 TR
I-C
A
P
A
C
IT
Y C
O
N
TR
O
L S
YS
TE
M
W
IR
IN
G
D
IA
G
R
A
M
3RD
P
A
RT
Y
CO
NT
RO
L
INT
E
RF
A
CE
CO
NNE
CT
IO
NS
1
R
E
M
OTE
ON
/OFF
N/
A
CO
M
M
O
N
(G
ND)
CO
M
M
O
N
(G
ND)
RT
N
A
IR
SE
NS
OR
(GND)
M
UL
TI
INP
UT
1
M
UL
TI
INP
UT
2
A
FT
E
R
HO
URS
10
7
6
8
9
5
4
3
2
14
16
13
15
12
11
RT
N
A
IR
S
E
NS
O
R
17
18
*
IM
PU
LSE
PU
SH
B
U
TT
O
N
N
/C
CONNE
CT
ION
SHOW
N
*
5
SE
C
CONT
A
CT
BRE
A
K
RE
QUI
RE
D
FOR
A
FT
ER
HOURS
A
CT
IV
A
TI
ON
3RD
P
A
RT
Y
CO
NT
RO
L
THE
RM
O
S
TA
T
0-
10
VDC
A
NA
LOGUE
INP
UT
F
OR
INDOOR
FA
N
SP
EE
D
ONL
Y
-
INDOOR
FA
N
SP
EE
D
OP
ERA
TI
ON
PROP
ORT
IONA
L
TO
0-
10
VDC
IN
PU
T
U
N
IT
F
A
N
SA
FET
Y
M
IN
&
M
A
X
SET
TI
N
G
S
ST
IL
L
A
PPL
Y
IF
0
-1
0V
IN
PU
T D
R
O
PS
B
EL
O
W
U
N
IT
M
IN
F
A
N
S
ET
TIN
G
- F
A
N
W
IL
L
R
U
N
A
T
M
IN
SPEED
DRM
1
DRM
2
DRM
3
DRM
CO
M
TH
ESE
TER
M
IN
A
LS
U
SED
F
O
R
DE
M
A
ND
M
A
NA
GE
M
ENT
VO
TA
G
E
FR
EE
R
EL
A
Y
R
EQ
U
IR
ED
DRM
1
=
COM
PRE
SS
ORS
OF
F
(0
%
)
DRM
2
=
COM
PRE
SS
OR
1
ONL
Y
(<
50
%
IN
PU
T
PO
W
ER
)
DRM
3
=
COM
PRE
SS
OR
2
ONL
Y
(<
75
%
IN
PU
T
PO
W
ER
)
SEE
M
U
LT
I I
N
PU
T
SEL
EC
TI
O
N
T
A
B
LE
FO
R
O
PT
IO
N
S
&
SEE
IN
ST
A
LL
A
TI
O
N
M
A
N
U
A
L
FO
R
C
O
N
N
EC
TI
O
N
/
SET
U
P
D
ET
A
IL
S
(N
O
TE:
SET
M
U
LT
I I
N
PU
T
1
TO
"
E"
-
0-
10
V
IN
F
A
N
C
O
N
TR
O
L
ONL
Y
1
OF
4
RE
M
A
INI
NG
OP
TI
ONS
CA
N
BE
S
EL
ECT
ED
FO
R
M
U
LT
I I
N
PU
T
2
*)
A
CT
RO
NA
IR
UNI
T
W
IRI
NG
3R
D
P
A
R
TY
C
O
N
TR
O
L IN
P
U
T TE
R
M
IN
A
LS
(3
S
TA
G
E C
O
O
L
/ 3
S
TA
G
E H
EA
T
/ R
EL
A
Y
O
U
T H
EA
T
&
IN
D
OOR
F
A
N
0-
10
V
A
NA
LO
G
UE
INDO
O
R
FA
N
SP
E
ED
CO
NT
RO
LL
ER
RE
Q
UI
RE
D
)
TR
I-C
A
P
A
C
ITY
C
M
10
0 C
O
M
M
E
R
C
IA
L C
O
N
TR
O
LS
3R
D
P
A
R
TY
TH
E
R
M
O
S
TA
T C
O
N
TR
O
LLE
R
C
O
N
N
E
C
TIO
N
24
V
A
C
R
E
LA
Y
O
U
TP
U
T FO
R
C
O
M
P
R
E
S
S
O
R
&
0
-1
0V
A
N
A
LO
G
U
E
O
U
TP
U
T FO
R
IN
D
O
O
R
FA
N
MULT
I I
NP
UT
MA
TRI
X
D
ESC
R
IPT
IO
N
D
COM
P
ST
A
GE
CONT
ROL
IN
-F
A
N
SPEED
C
O
N
TR
O
L
C
NI
GHT
M
ODE
B
ECONOM
Y
M
ODE
A
SU
PPL
Y
A
IR
T
EM
P
E
TY
PE
0-
10
V
A
NA
LOGUE
DI
GI
TA
L
INP
UT
DI
GI
TA
L
INP
UT
SEN
SO
R
0-
10
V
A
NA
LOGUE
M
U
LTI IN
P
U
T S
E
LE
C
TIO
N
TA
B
LE
"W"
O
PT
IO
N
3P
PR
O
TEC
TI
O
N
R
EL
A
Y
O
PT
IO
N
- M
U
LT
I IN
PU
T 2
D
IG
IT
A
L IN
PU
T
* F
A
C
TO
R
Y W
IR
ED
O
PT
IO
N
T
O
M
U
LT
I IN
PU
T 2
W
H
EN
"
W
" O
PT
IO
N
IN
ST
A
LL
ED
- N
O
A
D
D
IT
IO
N
A
L
M
U
LT
I I
N
PU
T
A
VA
IL
A
B
LE
0-
10
V
IN
D
O
O
R
F
A
N
S
PE
ED
C
O
N
TR
O
L
D
O
N
O
T
U
SE
W
H
EN
2
4VA
C
ST
A
G
E
IN
PU
T
TER
M
IN
A
LS
A
R
E
C
O
N
N
EC
TED
24
VA
C
IN
PU
T
FO
R
R
EV
ER
SI
N
G
VA
LV
E
(H
EA
T)
O
PER
A
TI
O
N
ST
A
G
E
C
O
N
TR
O
L
FO
R
H
EA
T
D
O
N
E
VI
A
C
O
M
P
ST
A
G
E
IN
PU
TS
24
VA
C
INP
UT
F
OR
INDOOR
FA
N
- F
A
N
ON
/OF
F
CONT
ROL
FO
R
C
O
N
TI
N
U
O
U
S
IN
D
O
O
R
F
A
N
O
PER
A
TO
N
U
SE
TH
IS
IN
PU
T
(IE
: I
NDOOR
FA
N
RE
M
A
INS
ON
W
HE
N
COM
P
C
YCL
ED
OF
F)
SET
C
P0
5/
10
C
O
N
TR
O
L
IN
TER
FA
C
E
TO
"
U
N
IT
O
FF
"
&
IN
D
O
O
R
FA
N
SET
TI
N
G
T
O
C
O
N
TI
N
U
O
U
S
24
VA
C
ST
A
G
E
C
O
N
TR
O
L
24
VA
C
S
U
PP
LY
F
R
O
M
A
C
TR
O
N
2
4V
A
C
O
U
T
TE
R
M
IN
A
L
IF
U
SI
N
G
2
ST
A
G
E
T/
ST
A
T
- C
O
N
N
EC
T
ST
A
G
E
1
TO
EI
TH
ER
C
O
M
P
1
(33%
)
O
R
C
O
M
P 2
(6
6%
) &
C
O
N
N
EC
T S
TA
G
E 2
T
O
C
O
M
P 3
(1
00
%
)
IN
D
O
O
R
F
A
N
W
IL
L R
U
N
W
H
EN
C
O
M
P IN
PU
TS
A
R
E A
C
TI
VE
.
(A
U
TO
M
O
D
E
- SET
C
P0
5/
10
C
O
N
TR
O
L
IN
TER
FA
C
E
TO
"
U
N
IT
ON"
&
INDOOR
FA
N
SE
TT
ING
TO
A
UT
O)
CONFIGUR
A
TION PR
O
CEDURE
C
ompressor: R
efer to Pro
ce
dure 18.
03
Fan: R
efer to Pro
ce
dure 18.
02
GND