background image

INTRODUCTION

INTRODUCTION

Thank you for selecting the Actiiv blood pressure Monitor  

(ACMMD001 .) The 

monitor features blood pressure measurement, pulse rate measurement and 

storage of results.

Readings taken by the device are equivalent to those obtained by a trained 

observer using the cuff and stethoscope auscultation method.

step instructions for using the product.

This manual contains important safety and care information, and provides step by 

Please read this user manual carefully and thoroughly before use.

FEATURES:

Systolic Blood Pressure

Diastolic Blood Pressure

Pulse Rate

Memory: Up to 60 readings can be

recorded

This product uses the Oscillometric Measuring Method to detect blood pressure. 

Before every measurement, the unit establishes a “zero point” equivalent to the 

atmospheric pressure. Then it starts inflating the cuff. Meanwhile, the unit detects

pressure oscillation generated by beat-to-beat pulsatile, which is used to deter-

mine the systolic pressure and diastolic pressure as well as pulse rate. 

The device also compares the longest and the shortest intervals of detected 

pulse wave with the average value, and then calculates the standard deviation.

The monitor will light up a warning symbol when the calculated standard deviation

is larger than or equal to 15. 

Measurement Principle

General Description

The below signs might appear in the user manual, labeling or other components. 

Safety information

2

3

Indications for use

The Actiiv Blood Pressure Monitor is a digital monitor intended for use in 

measuring blood pressure and heartbeat rate with a wrist circumference ranging

from 13.5 cm to 21.5 cm ( about 5-8.5 inches ). 

It is intended for adult  indoor use only.

CAUTION

* It is intended for adult indoor use only. Pregnant women, pre-eclamptic patients

and patients with severe obesity should not use this device. If required, please consult a 

professional doctor.

* This device is intended for non-invasive measuring and monitoring of arterial blood pressure. It is

not intended for use on extremities other than the wrist or for functions other than obtaining a

blood pressure measurement.

* Please use the device under the specified environment as instructed in this user manual,

otherwise the accuracy of the device will be influenced.

* Do not confuse self-monitoring with self-diagnosis. This unit allows you to monitor your blood

pressure. Please only start or end any medical treatments based solely on a physician's treatment 

advice.

* If you  are taking medication, consult your physician to determine the most appropriate time for

your measurement. Never change a prescribed medication without your physician’s consent.

* This unit is not suitable for continuous monitoring during medical emergencies or operations.

After the cuff has been inflated for a long time, the patient’s wrist and fingers blood supply will 

become insufficient and could result in distending pain and ecchymosis.

* If the pressure of the cuff exceeds 40 kPa (300 mmHg), the unit will automatically deflate. If the

cuff doesn’t deflate when its pressure exceeds 40 kPa (300 mmHg), detach the cuff from the wrist 

and press the START/STOP button to stop inflation.

* Do not use the monitor under strong electromagnetic field conditions (e.g. medical RF equipment) 

that radiate an interference signal or electrial fast transient/ burst signal.

* The maximum temperature that the applied part can achieve is 42.5 ℃ while the

environmental temperature is 40℃.

* The device is not AP/APG equipment. It is not suitable for use in the presence of a flammable

anesthetic mixture with air (or oxygen, nitrous oxide).

* Please keep the unit out of reach of infants, children or pets, since inhalation or swallowing of

small parts is dangerous or even fatal.

* Please use the accessories and detachable parts as specified and authorised by the manufacturer.

Otherwise, it may cause damage to the unit or danger to the user / patient.

* The patient is an intended operator. The patient can measure, transmit data and charge the battery

under normal circumstances and maintain the device and its accessories according to the user

manual.

* The blood pressure monitor, its adaptor, and the cuff are suitable for use within the patient

environment. If you are allergic to dacron or plastic, please don’t use this device.

*This device cannot be used with HF surgical equipment at the same time.

* There is a PTC current limiter in the monitor, with a specification of 8V and 0.5A. When the voltage

and current exceed the limiting value, the monitor will stop working.

   

   

 

 

 

 

* The device is not suitable for public use.

T1A/250V Φ3.6*10CCC

F1

For indoor use only

Symbol for “TYPE BF

APPLIED PARTS”

Symbol for “DIRECT

CURRENT”

The Bluetooth Combination

Mark

Symbol for “THE OPERATION 

GUIDE MUST BE READ”

Содержание ACMMD001

Страница 1: ... so as to ensure the safe usage of this product and keep the manual for further reference in case you have problems Thank you very much for selecting the Actiiv Wrist Blood Pressure Monitor ACMMD001 MODEL ACMMD001 WRIST BLOOD PRESSURE MONITOR User Manual ...

Страница 2: ...od pressure I get from the hospital different from home Will I get the same result if I measure on the right wrist TROUBLESHOOTING 19 SPECIFIC ATIONS 20 THE MATCHED COMPONENTS 21 CONTACT INFORMATION 21 Safety Information Charging your Device Setting Date and Time Positioning the Cuff Start Measurement DATA MANAGEMENT 13 Recall the Records Delete the Records COMPLIED EUROPEAN STANDARDS LIST 22 Pair...

Страница 3: ...ed Do not confuse self monitoring with self diagnosis This unit allows you to monitor your blood pressure Please only start or end any medical treatments based solely on a physician s treatment advice If you are taking medication consult your physician to determine the most appropriate time for your measurement Never change a prescribed medication without your physician s consent This unit is not ...

Страница 4: ...ear Low Battery Please use the USB cable provided to recharge the battery Error Memory Recalling the history records Bluetooth Successful Bluetooth Connection IHB Detector Irregular Heartbeat Detector Error 5 SYSTOLIC DIASTOLIC MEM UP BUTTON SET DOWN BUTTON START STOP BUTTON CUFF Type BF applied part PULSE RATE TIME USB Interface Monitor Components List 1 Blood Pressure Monitor ACMMD001 2 USB Cabl...

Страница 5: ...onitor in a cool dry and ventilated environment Avoid close proximity to fire and heat sources or it may cause the battery explode 4 You cannot use the blood pressure monitor during the charging process 5 During the process of charging the blood pressure monitor will display this symbol When charging is complete please remove plug before use 6 When charging do not touch the charging connector and t...

Страница 6: ...e edge of the cuff about 1 2 cm from bottom of hand 5 Fasten the wristcuffaroundyour wrist leaving no extra roombetweenthe cuff and your skin If the cuff is too loose the measurement will not be accurate Rest for 5 minutes before measuring Wait at least 3 minutes between measurements This allows your blood circulation to recover For a meaningful comparison try to measure under similar conditions F...

Страница 7: ...re able to receive your personal health data Just simply install the specially designed app and pair up your blood pressure monitor with your mobile phone by following the instructions below 1 The App is now available in the App Store and Google Play App name is LIFESENSE INTERNATIONAL You may search for the app then download and install the app on your iPhone or Android Phone Simple and convenien...

Страница 8: ...limb which other monitoring ME EQUIPMENT is applied simultaneously because this could cause temporary loss of function of those simultaneously used monitoring ME EQUIPMENT 4 Do not use the device in such a way as to cause prolonged impairment of blood circulation in the patient 13 Recall the Records 1 Press the MEM button to access the memory The monitor will display the calculated average of the ...

Страница 9: ...hutdown Under Memory Recalling Mode if you wish to give up clearing press START STOP to turn off the monitor 3 When there is no memory in the monitor if you press the MEM button to look up the history the LCD will display as pictured to the right CAUTION 15 Tips for Measurement Within 1 hour after eating or drinking Within 20 minutes after taking a bath In a very cold enviroment Immediate measurem...

Страница 10: ...stolic pressure When the ventricles relax the blood pressure reaches its minimum value in the cycle which is called diastolic pressure Irregular Heartbeat Detector This Blood Pressure Monitor is equipped with an intelligent Irregular Heartbeat IHB Detector function During each measurement this equipment records the heartbeat intervals and works out the standard deviation If the calculated value is...

Страница 11: ... Measured incorrectly Power is exhausted Charge the power Power is low Charge the power 1 Individual blood pressure varies every day It is also affected by the way you tie your cuff and your measurement position so please take the measure ment in the same conditions 2 Blood pressure variation is greater if the person takes medication 3 Make sure you wait at least 3 minutes before taking another me...

Страница 12: ...IP22 It means the device could be protected against solid foreign objects of 12 5 mm and greater and against vertically falling water drops when ENCLOSURE is tilted up to 15 Software version Device classification V01 Battery Powered Mode Internally Powered ME Equipment WARNING No modification of this equipment is allowed Rated cuff pressure 0kpa 40kpa 0mmHg 300mmHg pulse value 40 199 beat minute Pre...

Страница 13: ... General requirements for basic safety and essential performance IEC EN 60601 1 11 2010 Medical electrical equipment Part 1 11 General requirements for basic safety and essential performance Collateral standard Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment IEC EN 80601 2 30 2009 Medical electrical equipment Part 2 30 Particular...

Страница 14: ...o save Data this will remove the weight measurement and return to the Start menu 7 Press the Settings button in the top right corner 8 Press the Add button to add a device 9 Press the Bluetooth logo 10 Please ensure you pressand hold the Start button on the blood pressure monitor to initiate Pairing Mode 11 Once connected the device will show It is now ready to use 12 Your readings will be recorde...

Отзывы: