INFORMATION FOR USER
ABOUT BLOOD PRESSURE
MEM
SET
MEM
SET
MEM
SET
16
Maintenance
To obtain the best performance, please follow the below instructions.
Keep your device in a cool
dry place, avoid direct sunlight
and high temperatures
Avoid dropping or direct impact
Avoid dusty environments and
unstable surrounding temperatures
Use a slightly damp cloth to
remove any dirt
Avoid washing the cuff
MEM SET
MEM
SET
MEM SET
CAUTION
1. Please make sure the unit functions safely and that it is in proper working condition before use.
Don’t service or maintain while the device is in use.
2. If you have any problems with this device, such as setting up, maintaining or using, please
go to www.actiivfitness.com. Don’t open or repair the device by yourself.
3. Please report to Actiiv if any unexpected operation or events occur.
4. Cleaning: Dusty environments may affect the performance of the unit.
Please use a soft cloth to remove any dirt from the device and cuff before and after use.
17
What are systolic pressure and diastolic pressure?
press
artery
vein
blood discharging
Systolic
relax
blood entering
Diastolic
What is the standard blood pressure classification?
When ventricles contract and pump blood out
of the heart, the blood pressure reaches its
maximum value in the cycle, which is called
systolic pressure. When the ventricles relax,
the blood pressure reaches its minimum
value in the cycle, which is called diastolic
pressure.
Irregular Heartbeat Detector
This Blood Pressure Monitor is equipped with an intelligent Irregular
Heartbeat (IHB) Detector function. During each measurement, this equipment records
the heartbeat intervals and works out the standard deviation. If the calculated value is
larger than or equal to 15, this equipment will light up the IHB symbol on the screen
when displaying the measuring result.
CAUTION
The appearance of the IHB icon indicates that a pulse irregularity consistent with
an irregular heartbeat was detected during measurement. Usually this is NOT a
cause for concern. However, if the symbol appears often, we recommend you
seek medical advice. Please note that the device does not replace a cardiac
examination, but serves to detect pulse irregularities at an early stage.
Only a doctor can tell your normal BP range. Please
contact your doctor if your measuring result falls out of the
range. Kindly note that only a doctor can tell whether
your blood pressure value has reached a dangerous point.
The blood pressure classification published by the
World Health Organization (WHO) and the
International Society of Hypertension (ISH) in
1999 is as follows:
SYS
DIA
<120
<80
120-129
80-84
130-139
85-89
140-159
90-99
160-179
100-109
≥180
≥110
Level
Blood
Pressure (mm Hg)
Optimal
Normal
High-normal
Mild
Moderate
Severe
CAUTION
Avoid immersing your device