А1020 MIRA Lite Low-Frequency Ultrasonic Tomograph
Operation Manual
6
ACOUSTIC
CONTROL
SYSTEMS
1.1.1 Intended use and application range
А1020 MIRA Lite Low-Frequency Ultrasonic Tomograph is designed to test the constructions of concrete, reinforced concrete
and stone in order to search for cavities, channels, reinforcement, foreign inclusions, laminations, cracks and other cavities, empty,
as well as filled with liquid or solid material, different from the surrounding concrete in its physical and mechanical properties.
The device is designed to inspect constructions made of concrete, reinforced concrete and stone with one-sided access for the
purpose of evaluation of consistency of the construction, searching for foreign inclusions, cavities, misruns, laminations and cracks,
as well as thickness measurement of the tested object.
The device allows for quick and efficient inspection of extensive objects along with documentation of results and the opportu-
nity of their preliminary analysis.
Main application areas of the device:
- inspection of the reinforced-concrete buildings, facilities, bridges, tunnels, highways, landing areas under construction, as
well as those ones under operation and maintenance in order to check their integrity and reliability;
- determination of thickness of walls and ceilings made of concrete;
- search for cavities, channels, reinforcement in the concrete constructions, and estimation of its thickness and dimensions;
- inspection of the state of inaccessible surfaces of concrete walls, rough estimate of the surrounding environment (air,
ground and water);
- qualitative assessment of exploitable minerals in the mining industry.
1.1.2 Operating conditions
The device is designed for operation under the following environmental conditions:
- air temperature from - 10 to + 50 ˚С;
- relative air humidity up to 95 % at +35 ˚С.
GENERAL
INFORMATION
1.1 THE INTENDED USE OF THE DEVICE
1
Содержание A1020 MIRA Lite
Страница 2: ...А1020 MIRA Lite Low Frequency Ultrasonic Tomograph Operation Manual 2 ACOUSTIC CONTROL SYSTEMS ...
Страница 42: ...А1020 MIRA Lite Low Frequency Ultrasonic Tomograph Operation Manual 42 ACOUSTIC CONTROL SYSTEMS NOTES ...
Страница 43: ...А1020 MIRA Lite Low Frequency Ultrasonic Tomograph Operation Manual 43 ACOUSTIC CONTROL SYSTEMS ...