IP482 Industrial I/O Pack User’s Manual Counter Timer Module
__________________________________________________________________
_________________________________________________________________________________________
Acromag, Inc. Tel:248-295-0310 Fax:248-624-9234 Email:[email protected] http://www.acromag.com
50
Physical Configuration
Single Industrial Pack Module
Length
3.880 in. (98.5 mm)
Width
1.780 in. (45.2 mm)
Board Thickness
0.062 in. (1.59 mm)
Max Component Height
0.290 in. (7.37 mm)
Connectors
IP Logic Interface: 50-pin female receptacle header (AMP 173279-3 or
equivalent).
Field I/O: 50-pin female receptacle header (AMP 173279-3 or
equivalent).
Power
Requirements
Module
IP482
5V (
5%)
Typical
410mA
Max.
480mA
+/-12V (
5%)
Not used
Operating Temperature:
Standard Unit 0 to +70
C.
E Version -40 to 85
C.
Relative Humidity:
5-95% Non-Condensing.
Storage Temperature:
-55
C to +125
C.
Non-Isolated:
Logic and field commons have a direct electrical connection.
Resistance to RFI:
Complies with EN61000-4-3 (3 V/m, 80 to 1000MHz
AM & 900MHz. Keyed) and European Norm EN50082-1 with no digital
upsets.
Conducted R F Immunity (CRFI):
Complies with EN61000-4-6 (3V/rms,
150kHz to 80MHz) and European Norm EN50082-1 with no digital
upsets.
Electromagnetic Interference Immunity (EMI):
No register upsets under
the influence of EMI from switching solenoids, commutator motors,
and drill motors.
Surge Immunity:
Not required for signal I/O per European Norm
EN50082-1.
Electric Fast Transient Immunity EFT:
Complies with EN61000-4-4 Level 2
(0.5KV at field input and output terminals) and European Norm
EN50082-1.
6.0
SPECIFICATIONS
PHYSICAL
Table 6.1:
Power
Requirements
5V Maximum rise time of
100m seconds
ENVIRONMENTAL