Upon receipt of this product, inspect the shipping carton for evidence of 

mishandling during transit.  If the shipping carton is badly damaged or water 
stained, request that the carrier's agent be present when the carton is 
opened.  If the carrier's agent is absent when the carton is opened and the 
contents of the carton are damaged, keep the carton and packing material 
for the agent's inspection. 

 
For repairs to a product damaged in shipment, refer to the Acromag 

Service Policy to obtain return instructions.  It is suggested that salvageable 
shipping cartons and packing material be saved for future use in the event 
the product must be shipped. 
 

This board is physically protected with packing material and electrically 

protected with an anti-static bag during shipment.  However, it is 
recommended that the board be visually inspected for evidence of 
mishandling prior to applying power. 
 

 

 
 

Refer to the specifications for loading and power requirements.  Be sure 

that the system power supplies are able to accommodate the power 
requirements of the system boards, plus the installed Acromag board, within 
the voltage tolerances specified. 
 

Adequate air circulation must be provided to prevent a temperature rise 

above the maximum operating temperature and to prolong the life of the 
electronics.  If the installation is in an industrial environment and the board is 
exposed to environmental air, careful consideration should be given to air-
filtering. 
 
 

 
 
 
Remove power from the system before installing board, cables, 

termination panels, and field wiring.  

 

 

The AXM-VFX-EDK cannot stand-alone and must be mated with a 

compatible Acromag PMC-VFX module.  The default configuration of the 
control register bits at power-up is described in section 3. 

 
 
The AXM-VFX-EDK board has four front I/O connectors.  The first is a 

double row 14-pin 2mm header (male) for JTAG programming.  This is the 
standard Xilinx JTAG Header.  The second I/O interface is a double row 34-
pin 0.1” header (male).  A standard floppy drive cable can be used to 
connect to the interface.  The third and fourth I/O interfaces are 9-pin DSUB 
right-angle female connectors.  Note the cables are available from Acromag. 

2.0  PREPARATION 
FOR USE 

 

UNPACKING AND 
INSPECTION 

WARNING: This board utilizes 
static sensitive components 
and should only be handled at 
a static-safe workstation. 

CARD CAGE 
CONSIDERATIONS 

 
IMPORTANT: Adequate air 
circulation must be 
provided to prevent a 
temperature rise above the 
maximum operating 
temperature. 

BOARD 
CONFIGURATION 

Default Hardware 
Configuration 

Front Panel Field I/O 
Connector 

Содержание AXM-VFX-EDK

Страница 1: ...NCORPORATED Tel 248 295 0310 30765 South Wixom Road Fax 248 624 9234 P O BOX 437 Wixom MI 48393 7037 U S A solutions acromag com Copyright 2009 Acromag Inc Printed in the USA Data and specifications a...

Страница 2: ...iguration 6 AXM VFX EDK Front I O 7 Non Isolation Considerations 8 3 0 PROGRAMMING INFORMATION MEMORY MAP 9 Board Status and Reset Register 10 Differential I O Registers 11 Differential Direction Cont...

Страница 3: ...____________________________ Acromag Inc Tel 248 295 0310 Fax 248 624 9234 Email solutions acromag com http www acromag com 3 6 0 SPECIFICATIONS PHYSICAL 18 ENVIRONMENTAL 18 LVTTL INPUT OUTPUT 19 DRAW...

Страница 4: ...G LVTTL RS232 Xilinx Std JTAG 34 Pin 0 1 Header Two DP9 0 C to 70 C Digital Input Output Channels Thirty 3 3 volt LVTTL CMOS compliant input output channels which can be configured as input or output...

Страница 5: ...board allows programming via the JTAG interface program display and general program debug and development Refer to the PMC base board s manual for further information on the available Engineering Desi...

Страница 6: ...ements of the system boards plus the installed Acromag board within the voltage tolerances specified Adequate air circulation must be provided to prevent a temperature rise above the maximum operating...

Страница 7: ...talled This allows for full end user customization These pins correspond to the 12 channels of Digital I O on the AXM D03 module Refer to the Digital I O Register section for further information The c...

Страница 8: ...AUX Channel 11 4 AUX Channel 4 5 Not Available 5 AUX Channel 5 6 Not Available 6 AUX Channel 6 7 Not Available 7 AUX Channel 7 8 Not Available 8 9 Pin DSUB Connections Pin Description Connections Pin...

Страница 9: ...gister and Software Reset2 8000 8007 29 0 EDK I O Register3 8004 800B Direction Register EDK Channels 29 03 8008 800F 15 0 Digital I O Register3 800C 8013 Direction Register Digital Channels 15 03 801...

Страница 10: ...ter reflect the status of each of the Differential I O channels 8 to 15 A Read of this bit reflects the interrupt pending status Read of a 1 indicates that an interrupt is pending for the correspondin...

Страница 11: ...els are set by writing to this register Note that the data direction input or output must first be set via the Differential Direction register at PCIBAR2 plus 8008H D31 D30 D29 D28 D27 D26 D25 Not Use...

Страница 12: ...tion of each channel is controlled by its corresponding data bit Data bit use varies depending on the module selected The bit mapping corresponds to the Differential and EDK I O Register Independent c...

Страница 13: ...use 8 bit 16 bit or 32 bit data transfers with the lower ordered bits corresponding to the lower numbered channels for the register of interest All input output channels are configured as inputs follo...

Страница 14: ...D1 D0 VFX EDK I O 15 I O 14 I O 13 I O 12 I O 11 I O 10 I O 9 I O 8 Interrupt Type COS or H L Configuration Register Read Write PCIBAR2 8018 The Interrupt Type Configuration Register determines the ty...

Страница 15: ...ata register A 1 bit means that an interrupt will occur when the input channel is high i e a 1 in the differential input channel data register Note that no interrupts will occur unless they are enable...

Страница 16: ...AXM D02 the 22 differential I O on the AXM D03 and 30 LVDS I O on the AXM D04 The 16 auxiliary I O map to the 16 differential signal on the AXM D03 Note that regardless of which AXM D module is being...

Страница 17: ...Also refer to the documentation of your carrier CPU board to verify that it is correctly configured Replacement of the board with one that is known to work correctly is a good technique to isolate a f...

Страница 18: ...150 C Non Isolated Logic and field commons have a direct electrical connection Radiated Field Immunity RFI Complies with EN61000 4 3 3V m 80 to 1000MHz AM 900MHz keyed and European Norm EN50082 1 with...

Страница 19: ...able with I O connections in shielded enclosure are required to meet compliance Mean Time Between Failure Contact the Factory Channel Configuration 42 Channels AXM VFX EDK Bi directional LVTTL signals...

Страница 20: ...NYLON SCREWS x2 PMC CONNECTOR MEZZANINE CONNECTOR COMPONENTSIDEOFAXMMODULE 4 THE SCSI CONNECTOR CAN BE FURTHER SECURED TO THE BOARD WITH 2 ADDITIONAL SCREWS D 3 SECURE THE AXM MODULE WITH NYLON STAND...

Страница 21: ...________________________ ________________________________________________________________________ Acromag Inc Tel 248 295 0310 Fax 248 624 9234 Email solutions acromag com http www acromag com 21 12 2...

Отзывы: