background image

安科瑞电气股份有限公司

 

 

32 

30257- 
30258 

S

 

S total 

0.0~99999999.99KVA(VA)

[8]

 

Float 

30259- 
30260 

频率

  Freq 

Frequency Freq 

45.0~65.0 

Float 

30261- 
30262 

电能

(

16

Electrical energy(Hi 

16) 

0.0~99999999.99KWh 

Float 

30263 

电量单位设置

 

Electirc uint set 

 

R/W 

电量单位设置:

0-KV,1-V 

Electirc uint setting

0-KV,1-V 

 

Word 

30264 

接线类型设置

 

Line mode set 

R/W 

接线类型设置:

0-3P3W,1-3P4W 

Electirc uint setting

0-3P3W,1-3P4W 

 

Word 

注:

[1] 

地址:

10001

—功能码为

02

,地址从

0

开始;

30001

—功能码为

03/04

,地址从

0

开始(

Address: 

10001-function code is 02, address is from 0; 30001-function code is 03/04, address is from 0

)。

 

[2]

 

属性:

R

—只读;

R/W

—可读可写(

Attribute

R-Read; R/W-Read/Write

)。

 

 

[3] 

×

10

—读取时实际值乘以相应的倍数上传,写入时应乘以相应的倍数写入(

Read  with  the 

ratio and write with the ratio in the table

)。

 

[4] 30117

0074H

地址,

ATC300

环境温度寄存器,

V1.36

及以上支持(

30117

0074H Address

 

ambient temperature from ATC300 register, support V1.36 or above

)。

 

[5]30118~30123

75H~7AH

,时间存储寄存器,对时必须

7

个寄存器写入,且不能超过范围

30118~30123

75H~7AH, Time register

  if master send time data into device, it must be 7 registers 

and forbid to write data out of range in the table

)。

 

[6]30125~30148

7CH~93H

,相见温度告警状态寄存器和相见温度定值寄存器,

V1.60

及以上支

持(

30125~30148

7CH~93H  Address

the  meet  temperature  alarm  status  register  and  the  meet 

temperature setting register, support V1.60 or above

)。

 

[7]30209~302,264

D0H~107H

,电量参数寄存器,

V1.60

及以上支持(

30209~30264

D0H~107H 

Address

electric quantity parameter register, support V1.60or above

)。

 

[8]

 

电量单位依据

30264

电量单位设置(

Electric  quantity  unit  is  set  according  to  30237  electric 

quantity unit

)。

 

注意:参量地址表与软件版本有关,请注意版本号,此表适用于

V1.38

及以上版本,如有任何

疑问,请联系我们。(

Parameter address table related to software version, please pay attention to the 

version

this table is suit forV1.38 and above

if you have any questions, please contact us.

 

 

 

Содержание ARTM-Pn

Страница 1: ...234 ARTM Pn ARTM Pn wireless temperature measuring equipment V1 9 Installation Operation Manual V1 9 Acrel Co LTD...

Страница 2: ...ns electronic mechanical photocopying recording or otherwise without prior permission of our company The violator will bear the dependent legal responsibility We reserve all the rights We reserve all...

Страница 3: ...perature Coordinator Installation 6 1 4 4 7 1 4 4 Wireless Temperature Sensor Installation 7 1 5 14 1 5 Wiring Method 14 1 5 1 14 1 5 1 Wiring Connector 14 1 5 2 15 1 5 2 DI Wiring Diagram 15 1 5 3 15...

Страница 4: ...Measuring 20 2 2 5 20 2 2 5 Electric power parameter measurement 20 2 3 ARTM Pn 21 2 3 ARTM Pn Operation Method 21 2 4 ARTM Pn 24 2 4 ARTM Pn Operation Process 24 3 25 3 Communications 25 3 1 25 3 1 C...

Страница 5: ...er Address Table 28 4 33 4 The Analysis and Solvent of Some Faults 33 4 1 33 4 1 Power Source Fault 33 4 2 33 4 2 Relay Output Fault 33 4 3 33 4 3 Communication Fault 33 4 4 34 4 4 Wireless Temperatur...

Страница 6: ...g built in switchgears handcart switchgears fixed switchgears and loop net switchgears It is also suitable for 0 4kV low voltage switchgears such as fixed switchgears and drawer switchgears The wirele...

Страница 7: ...cy 50Hz Accuracy rating Current Voltage 0 5 0 5 class Active power 0 5 0 5 class ARTM Wireless temperature measuring equipment Pn P3 P6 P9 P12 3 6 9 12 60 P3 P6 P9 or P12 selectable n 60 x00 Sensor Ty...

Страница 8: ...MTBF 50000 h Active wireless temperature sensor Wireless frequency 470MHz Communication distance 150m 150m in open area Sampling frequency 25s Transmitting frequency 25s 5min Power source Battery Ins...

Страница 9: ...on 1 Application Joints in high or low voltage switchgears Outdoor wireless temperature sensor Wireless frequency 470MHz Communication distance 150m 150m in open area Sampling frequency 25s Transmitti...

Страница 10: ...is installed with the front panel embedded First make a square hole on the switchgear surface to the specified size Then separate the two brackets from device and embed the device into the square hole...

Страница 11: ...6 1 4 3 1 4 3 Wireless Temperature Coordinator Installation ARTM Pn DIN35mm The wireless temperature coordinator connected with ARTM Pn which can be mounted on rail DIN35mm or bolted directly...

Страница 12: ...nstalled in instrument chamber circuit breaker chamber or cable chamber ther installation examples see images below 1 4 4 1 4 4 Wireless Temperature Sensor Installation There are several types of wire...

Страница 13: ...8 ATE100M ATE100 ATE100P ATE200 ATE200P...

Страница 14: ...ee images above if the sensor is ATE100M ATE100 ATE200 ATE400 ATE100P ATE200P the number behind should be same as number underlined in 51809190240001 the sequence of installation is base on the label...

Страница 15: ...Structure introduction of ATE100M 1 The core of wireless temperature sensor ATE100M 2 Thermo sensitive part 3 battery switch Adsorbed directly at the iron temperature measuring point open the battery...

Страница 16: ...tallation examples see images below 1 4 4 5 ATE200 1 4 4 5 ATE200 Installation Method ATE200 The strap secured type called ATE200 is suitable for use at moving contacts and fixed contacts of breaker c...

Страница 17: ...e images below 1 4 4 6 ATE400 1 4 4 6 ATE400 Installation Method ATE400 The mini type called ATE400 is suitable for using at moving contacts bus bars cables and joints between bus bar and cable Mini t...

Страница 18: ...ilicone gasket the core of ATE400 and another silicone gasket in turn Thirdly circle the whole alloy chips around the mounting position and tension the alloy chips then tighten the screw on the metal...

Страница 19: ...14 1 5 1 5 Wiring Method 1 5 1 1 5 1 Wiring Connector 61 62 63 64 Wireless Temp 12 A 3 13 14 4 B 6 RS485 5 7 1 21 22 23 24 2 DI1 DI2 L N Power Relay Output R1 R2 DI4 DI3 Reserve VCC Tx Rx GND...

Страница 20: ...15 1 5 2 1 5 2 DI Wiring Diagram 1 5 3 1 5 3 DO Wiring Diagram 1 5 4 1 5 4 ELEC Wiring Diagram...

Страница 21: ...ve Wireless Temperature Sensor Solution Battery powered Active wireless temperature sensor solution list Name Type Count wireless temperature measuring equipment ARTM Pn 100M 100 200 1 1 Connected cab...

Страница 22: ...100 200 ATE400 The device can receive 60 wireless temperature sensors make a reasonable configuration with count of sensors according to the transmission distance In principle ATE100M 100 200 ATE400...

Страница 23: ...18 1 7 1 7 System Solution 2 2 Product Operation Guide ARTM Pn The operation guide is suitable for ATRM Pn wireless temperature measuring equipment Substation Communication Devices...

Страница 24: ...struction 2 2 2 2 Operation Instruction 2 2 1 2 2 1 Device Power On After connecting with suitable power source the device will be worked 2 2 2 2 2 2 Digital Input Back Change Left Number LCD LCD Disp...

Страница 25: ...rature sensor group 6 over temperature The high temperature alarm is first relay output the over temperature alarm is second relay output Notice it is valid only when the Node Enable of sensor group i...

Страница 26: ...nge the temperature interface 2 SET Enter 2 In temperature submenu press SET button it will be back to main menu interface in main menu each submenu consist of icon and title press the left or right b...

Страница 27: ...ure threshold including the Node Enable high temperature and over temperature and compare values For example if Node1 Enable is ON the relay output contact will be closed while the node1 group tempera...

Страница 28: ...of sensors User can input sensor ID manually if the version is V1 36 and above Enter Enter SET Enter SET Calibrate we can calibrate the temperature values of registered sensors the method is enter the...

Страница 29: ...s SET if modified prompt information will be show on the screen press Enter button to confirm press Set button to cancer 11 11 In main menu select Info submenu and confirm then enter the Information i...

Страница 30: ...Modbus This chapter focuses on how to use software to control the device through RS485 communication port The mastery of the content in this chapter requires that you have the knowledge reserve of Mod...

Страница 31: ...Addr Fun Byte count 1 Data 1 2 Data 2 3 Data 3 CRC16 CRC16 Hi Lo Hi Lo Hi Lo Hi Lo 01H 02H 06H 00H 00H 00H 00H 00H FCH E0H F8H 3 1 2 03H 04H 3 1 2 Read Data Function code 03H 04H This function allows...

Страница 32: ...n Register Addr Value CRC16 CRC16 Hi Lo Hi Lo Hi Lo 01H 06H 00H 03H 03H E8H 74H 79H 3 1 4 10H 3 1 4 Preset Multi Registers Function code 10H User can write active parameter into the multi registers wi...

Страница 33: ...0147 10152 Reserved R Reserved for filling full byte bit 6 30001 Address R W 001 247 Word 30002 Baud rate R W 2400 4800 9600 19200 Word 30003 Backlight time R W 000 999s 000 000 999s 000 is for lighti...

Страница 34: ...3 Over temperature Alarm state 3 R 0 1 bit0 bit14 11A 15C 0 normal 1 alarm bit0 bit14 Node11A Node 15C over temperature Word 30014 4 Over temperature Alarm state 4 R 0 1 bit0 bit14 16A 20C 0 normal 1...

Страница 35: ...t0 bit14 Node6A Node 10C compare temperature Word 30127 3 Compare temperature Alarm state 3 R 0 1 bit0 bit14 11A 15C 0 normal 1 alarm bit0 bit14 Node11A Node 15C compare temperature Word 30128 4 High...

Страница 36: ...25 30226 Ic R 0 0 99999999 99 Primary Side 0 0 99999999 99 Float 30227 30228 PA R 0 0 99999999 99KW W 8 Float 30229 30230 PB R 0 0 99999999 99KW W 8 Float 30231 30232 PC R 0 0 99999999 99KW W 8 Float...

Страница 37: ...0074H Address ambient temperature from ATC300 register support V1 36 or above 5 30118 30123 75H 7AH 7 30118 30123 75H 7AH Time register if master send time data into device it must be 7 registers and...

Страница 38: ...r source connector and power on it again 4 2 4 2 Relay Output Fault When measured wireless temperature values exceed the setting values the relay output does not work Reason Node Enable is not ON Solv...

Страница 39: ...heck up the active wireless temperature whether its battery switch is ON When the battery switch turn to ON from OFF the green light will lighting twice it is worked otherwise wait for 5s and turn on...

Отзывы: