4. maintenance and troubleshooting tips
4.1 routine maintenance operations
Before you perform any maintenance work, make sure you switch the blower off
by pressing until the ON LED goes out.
High-quality materials and surface treatment protect your appliance against
corrosion and impacts.
To maximise the service life of your radiator, we recommend you take the
following precautions:
- Never use abrasive or corrosive products on the outer surfaces of the appliance
(except the electrical parts); use warm, soapy water.
- Use a soft, dry cloth without any solvents to clean the blower and the remote
control.
ImPOrTAnT
If the power cable is damaged, for safety reasons it must be replaced
by the manufacturer, the manufacturer’s after-sales service department or a
similarly qualified person.
4.2 Cleaning the filter
With time, the dust build-up may cause the filter situated at the rear of the blower
to clog. After approximately 200 hours of blower operation, the FILTER alarm LED lights
up to indicate the need to clean the filter.
Regular filter cleaning is therefore necessary for the blower to function correctly
and efficiently.
Pull out the filter situated at the rear of the blower and wash it in warm water
(then leave to dry) or clean it with a vacuum cleaner. During this process, and in order
to protect your appliance, the alarm LED lights up, thereby preventing the blower
from functioning.
After cleaning the filter, reposition it in its seat and secure it in its original
position.
no Parameter
description
default setting
Setting
0
Boost time
Adjustable from 15 to 120
minutes in 15-minute
increments
30 minutes
Press the
+
or
-
key
1
Programme P1
time
Adjustable from 15 to 120
minutes in 15-minute
increments
- If parameter 3 = 0
or 2: 30 minutes
Press the
+
or
-
key
- If parameter 3 = 1:
60 minutes
2
Programme P2
time
Adjustable from 15 to 120
minutes in 15-minute
increments
- If parameter 3 = 0
or 2: 30 minutes
Press the
+
or
-
key
- If parameter 3 = 1:
60 minutes
3
Type of
programme
Value 0 (blower only), 1
(radiator on boost) or 2
(radiator on boost + blower)
1
Press the
+
or
-
key
4
Setpoint tempera-
ture calibration
Adjustable between -5.0°C
to 5.0°C in 0.5°C increments
0,0°C
Press the
+
or
-
key
5
Room temperature
calibration
Not available on this model
--
6
Type of energy
source
NEVER modify! *
1
7
Default display
Value 0 (time) or 1 (setpoint
temperature)
1
Press the
+
or
-
key
8
Version number
display and reset
Reset to factory settings.
Press the
+
key
for 10 seconds
The time will have to be
re-set.
end
Quitting parameter
settings display
Quit parameter setting menu
Press
P2
* The remote control parameters are set according to the power supply of your towel radiator (hot
water or electricity). We advise against modifying the default value.