2.2 Positioning your appliance
To get the most out of your appliance and enjoy the highest standards of comfort,
we recommend that you:
- install the appliance near places with high heat loss (windows, doors, etc.)
wherever possible;
- ensure that the bottom of the junction box s positioned at least 10 cm above the
floor.
To ensure your system is safe:
- ensure that an area of at least 50 cm in front of the appliance is clear of objects
which might hinder air circulation (furniture, armchairs, etc.);
- position a shelf at least 10 cm above the top of your radiator;
- use mounting screws suitable for your wall.
ImPOrTAnT
The heating appliance must not be placed underneath a power
outlet.
You will find a complete set of assembly instructions in your appliance's box.
2. Installing your appliance
2.1 Installation restrictions
The flexible cable supplied with your appliance is designed to be connected to
the mains via a junction box that must be placed behind the appliance, with no need
for a plug.
In a kitchen or bathroom, the junction box must be positioned at least 25 cm
from the floor.
The appliance must be installed as described in this document and in accor-
dance with the applicable European and French standards, including CEI 60364.7.701
and NF C15-100, as well as the rules of good professional practice.
For other countries (apart from France), the appliance must be installed in
accordance with standards in force and with rules of good professional practice in the
country of use.
ImPOrTAnT
The example shown only concerns a bathtub. For other bathroom fixtures,
please consult your installer.