CARTRIDGE REPLACEMENT/ STRAINER MAINTENANCE
Note: Use the universal maintenance tool to perform the following:
1. Strainer plug must be removed before cartridge replacement and strainer
maintenance (no need to turn the water off at the angle stop). Some residual water will drain
during plug removal.
2. Clean strainer as needed using clean water.
3. Cartridge replacement - insert diamond end of the universal tool into push button, rotate 90 degrees
and pull firmly to remove the button. Remove cartridge retaining nut . Remove and replace cartridge.
When replacing cartridge be sure to align the inlet and outlet ports on the cartridge with the ports in
the valve body.
NOTE: STRAINER SCREEN MUST BE IN PLACE FOR WATER TO FLOW.
CARTRIDGE VALVE PARTS BREAKDOWN
ACORN ENGINEERING FIELD SERVICE
TOLL FREE
800-743-8259 •
LOCAL
626-855-4866 •
FAX
626-855-4863
7020-905-001
Page 7 of 11
Repairs must be made with Acorn Engineering parts only. Please order through your local representative
or distributor. The phone to locate your local representative is 1.800.591.9360
ITEM
PART NUMBER
DESCRIPTION
5
7003-830-000
UNIVERSAL MAINTANANCE TOOL
4
7003-864-000
STRAINER FILTER SCREEN
3
7003-097-001
O-RING &STRAINER PLUG
2
7000-060-000
FLOW REGULATOR CARTRIDGE(05 GPMG)
1
7003-095-001
VALVE ASSEMBLY
2
4
3
1
5
Date: 08/11/14
Please visit
for most current specifications.
www.acorndrinkingfountains.com
INSTALLATION, OPERATIONS & MAINTENANCE MANUAL