background image

 

ACORN ENGINEERING FIELD SERVICE

TOLL FREE

 800-743-8259 • 

LOCAL

  626-855-4866 • 

FAX

 626-855-4863

7020-905-001

Page 10 of 11

Repairs must be made with Acorn Engineering parts only. Please order through your local representative 
or distributor. The phone number to locate your local representative is 1.800.591.9360. 

1

2

3

11

5

6

5

9

4

8

8

7

10

12 13

16

14

15

27"

27

24

17

17

16

15

34"

25

26

23

22

21

19

18

20

33

15 16

15"

29

28

31

30

32

28

29

34

38

39

41

40

39

37

38

35

36

38

43

42

39

44

11

15 16

15"

NOTE:

 29  Flow Restrictor Only Available
  With Low Flow Bubbler.

Universal Maintenance Tool

-Button Removal
-Cartridge Retaining Nut
-Strainer Plug
-Removal of P.E. Tubing from
 Push-in Fittings

32

SENSOR OPERATED WATER COOLER PARTS BREAKDOWN DRAWING:
NOTE: 

See page 11 for table of part numbers corresponding to drawing below.

Date: 08/11/14

Please visit 

 

for most current specifications.

www.acorndrinkingfountains.com

 

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Содержание A172.8UBL Series

Страница 1: ...ed by other causes such as mishandling or improper care or abnormal use The repair or replacement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Acorn...

Страница 2: ...nt ROUGHING IN AND DIMENSIONAL DRAWING Prior to roughing consult with local state and federal codes for proper mounting height A172 8UBL SERIES REFRIGERATED BI LEVEL WALL MOUNTED WATER COOLER Note the...

Страница 3: ...ng current Acorn Engineering installation instructions and if components are assembled to the fixture that is not approved by Acorn Engineering 10 Fixture operates within water pressure range of 20 to...

Страница 4: ...rackets ensuring the bracket tabs engage AND seat in the slots in the back of the water coolers NOTE Hanging of refrigerated unit first is recommended since it is the heavier of the two Verify water c...

Страница 5: ...d screwdriver and turning clockwise to make colder and counterclockwise to make warmer c Bubbler Stream Bubbler can be rotated slightly to direct the stream backwards or forwards Adjust the stream to...

Страница 6: ...with installation materials such as pipe dope and flux The screen should be cleaned and checked on a regular basis and replace if needed NOTE STRAINER SCREEN MUST BE IN PLACE FOR WATER TO FLOW e The c...

Страница 7: ...on the cartridge with the ports in the valve body NOTE STRAINER SCREEN MUST BE IN PLACE FOR WATER TO FLOW CARTRIDGE VALVE PARTS BREAKDOWN ACORN ENGINEERING FIELD SERVICE TOLL FREE 800 743 8259 LOCAL...

Страница 8: ...nsure that the water line is depressurized Push collet square towards the push in fitting body and hold While holding the collet in pull on the PE tubing to remove from the push in fitting TO CUT TUBE...

Страница 9: ...t Strainer Plug Removal of P E Tubing from Push in Fittings 32 NOTE 29 Flow Restrictor Only Available With Low Flow Bubbler 1 2 3 11 5 6 5 9 4 8 8 7 10 12 13 16 14 15 27 27 24 17 17 16 15 34 25 26 23...

Страница 10: ...15 34 25 26 23 22 21 19 18 20 33 15 16 15 29 28 31 30 32 28 29 34 38 39 41 40 39 37 38 35 36 38 43 42 39 44 11 15 16 15 NOTE 29 Flow Restrictor Only Available With Low Flow Bubbler Universal Maintenan...

Страница 11: ...7012 062 001 FAN MOTOR 220V 19 7003 350 000 FAN BLADE 20 7003 201 000 CONDENSER 7012 801 000 COMPRESSOR 7012 030 001 COMPRESSOR 220V 7012 802 000 START RELAY 7012 031 000 START RELAY 220V 7012 803 00...

Отзывы: