NOTES:

1. Dimensions shown for ADA compliant installation. For Child ADA 2010 compliant parallel approach 

installation, decrease height of * dimensions by 2-3/4".

2. Provide clear floor space as required. Adjust vertical dimensions as required to comply with federal,

state, and local codes.

See next page for alternative mounting of units, roughing-in and dimensional drawing.

IMPORTANT

This fixture is intended to dispense water that has been lowered in temperature, but otherwise remains 
unchanged by the materials in the water cooler. It is common for electrical equipment to be grounded 
to water lines either within a structure or away from it. Every attempt should be made to prevent this 
kind of grounding from generating electrical feedback into the water cooler creating electrolysis. 
Electrolysis will cause a metallic taste or cause water metal content to increase.

NOTICE

A dielectric coupling must be used to connect the water cooler to the water supply . A nonmetallic 
coupler is furnished with this water cooler to meet this requirement.

ROUGHING-IN AND DIMENSIONAL DRAWING

Prior to roughing consult with local, state, and federal codes for proper mounting height.

A172.8UBL SERIES REFRIGERATED BI-LEVEL WALL MOUNTED WATER COOLER

Note: there are no mounting changes to be made for -SO models.

ACORN ENGINEERING FIELD SERVICE

TOLL FREE

 800-743-8259 • 

LOCAL

  626-855-4866 • 

FAX

 626-855-4863

7020-905-001

Page 2 of 11

GENERAL NOTES:
1. ALL DIMENSIONS ARE IN INCHES [MM]
2. ALLOW 4 INCHES [102 MM] MINIMUM CLEARANCE PER SIDE FOR VENTILATION

*3. DIMENSIONS SHOWN ARE FOR RECOMMENDED ADULT HEIGHT. ADJUST VERTICAL

DIMENSIONS AS NECESSARY TO COMPLY WITH FEDERAL, STATE, & LOCAL CODES.

4. STOP VALVE, P-TRAP, & ELECTRICAL OUTLET NOT SUPPLIED.
5. IMPORTANT: COOLERS MUST BE ATTACHED TO WALL WITH APPROPRIATE WALL

ANCHOR SCREWS.

A. 3/8" NCT SUPPLY INLET

B.  WASTE OUTLET FOR 1-1/4" P-TRAP BY OTHERS.
C. ELECTRICAL SERVICE ROUGH.
D. Ø3/8" HANGER BRACKET PUNCHING, 3 PLACES FOR ANCHORING HARDWARE BY OTHERS.
E. Ø1/4" PUNCHING, 2 PLACES FOR ANCHORING HARDWARE BY OTHERS.

AIR FLOW

11"

16

5
8

"

20

1
2

"

3

7
8

"

13

1
2

"

5

1
4

"

7

7
8

"

18

1
2

"

1

3
8

"

6"

12"

TAIL

PIECE

*33"

7

1
4

"

6"

2

1
4

"

4

1
4

"

D

E

A

B

C

6

5
8

"

18

5
8

"

9

1
4

"

*21

5
8

"

Date: 08/11/14

Please visit 

 

for most current specifications.

www.acorndrinkingfountains.com

 

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Содержание A172.8UBL Series

Страница 1: ...ed by other causes such as mishandling or improper care or abnormal use The repair or replacement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Acorn...

Страница 2: ...nt ROUGHING IN AND DIMENSIONAL DRAWING Prior to roughing consult with local state and federal codes for proper mounting height A172 8UBL SERIES REFRIGERATED BI LEVEL WALL MOUNTED WATER COOLER Note the...

Страница 3: ...ng current Acorn Engineering installation instructions and if components are assembled to the fixture that is not approved by Acorn Engineering 10 Fixture operates within water pressure range of 20 to...

Страница 4: ...rackets ensuring the bracket tabs engage AND seat in the slots in the back of the water coolers NOTE Hanging of refrigerated unit first is recommended since it is the heavier of the two Verify water c...

Страница 5: ...d screwdriver and turning clockwise to make colder and counterclockwise to make warmer c Bubbler Stream Bubbler can be rotated slightly to direct the stream backwards or forwards Adjust the stream to...

Страница 6: ...with installation materials such as pipe dope and flux The screen should be cleaned and checked on a regular basis and replace if needed NOTE STRAINER SCREEN MUST BE IN PLACE FOR WATER TO FLOW e The c...

Страница 7: ...on the cartridge with the ports in the valve body NOTE STRAINER SCREEN MUST BE IN PLACE FOR WATER TO FLOW CARTRIDGE VALVE PARTS BREAKDOWN ACORN ENGINEERING FIELD SERVICE TOLL FREE 800 743 8259 LOCAL...

Страница 8: ...nsure that the water line is depressurized Push collet square towards the push in fitting body and hold While holding the collet in pull on the PE tubing to remove from the push in fitting TO CUT TUBE...

Страница 9: ...t Strainer Plug Removal of P E Tubing from Push in Fittings 32 NOTE 29 Flow Restrictor Only Available With Low Flow Bubbler 1 2 3 11 5 6 5 9 4 8 8 7 10 12 13 16 14 15 27 27 24 17 17 16 15 34 25 26 23...

Страница 10: ...15 34 25 26 23 22 21 19 18 20 33 15 16 15 29 28 31 30 32 28 29 34 38 39 41 40 39 37 38 35 36 38 43 42 39 44 11 15 16 15 NOTE 29 Flow Restrictor Only Available With Low Flow Bubbler Universal Maintenan...

Страница 11: ...7012 062 001 FAN MOTOR 220V 19 7003 350 000 FAN BLADE 20 7003 201 000 CONDENSER 7012 801 000 COMPRESSOR 7012 030 001 COMPRESSOR 220V 7012 802 000 START RELAY 7012 031 000 START RELAY 220V 7012 803 00...

Отзывы: