background image

 

 

09-11-2018 · ACO FUNKI · Tlf. 97119600 · www.acofunki.com 

Page 8

   

 

MASTER CHAIN

®

 

 

FEEDING SYSTEM

 

 

 
Assembly 

 
Loading hopper 
 

Place the loading hopper below the silo. The station may be attached directly to the silo using bolts or attached via 
a funnel installed on top of the loading hopper.  

 

The loading hopper is supplied with or without gate. If the silo does not have a gate we recommend you select a 
loading hopper with a gate. 
 
If you use a funnel and your silo has a gate, the top edge of the funnel must be lower than the silo gate, allowing 
it to open freely. 
 
In  outdoor  installations  we  recommend  the  loading  hopper  to  be  protected  with  a  cover  to  prevent  water 
percolation. 
 
Attach  the  loading  hopper  directly  to  the  floor  using  coach  screws  or  mount  on  adjupig  barn  legs  to  adapt  the 
height to the silo. 
 
Mount the inspection pipe after the outlet pipe on the loading hopper using a splicing sleeve. Place the inspection 
pipe so that the oblong hole is horizontal, and covered by the slotted plastic tube. Attach the plastic tube to the 
inspection pipe using two clamps. 
 
The inspection pipe allows the user to see how full the feed pipe is, thus checking the adjustment of the  loading 
hopper. 

 
 

 

Adjustment 

The loading hopper is fitted with a motor that drives a horizontally rotating arm via an axle. The rotation of the 
arm  causes  continuous  administering  of  feed  to  the  feeding  system  to  occur,  thus  preventing  overload  and 
blocking. The feed quantity may be adjusted using a turnable dosing gate. 
 
Considering the load and operating reliability of the system, we recommend the feed quantity to be set so that the 
feed pipe is approximately half full. The feed pipe must never be more than two thirds full. 

 

 

Dosing Gate 

Rotating direction 

Содержание Egebjerg MASTER Chain

Страница 1: ...09 11 2018 ACO FUNKI Tlf 97119600 www acofunki com Egebjerg MASTER Chain feeding system 84 001 UK...

Страница 2: ...nit 7 Sensor switch 7 Assembly 8 Loading hopper 8 Adjustment 8 Drive unit 9 Feed pipes 9 Splicing sleeves 10 Bends 10 Feed outlet 10 Plastic feed dispensers 11 Sensor switch 11 Feed wire 12 Feed chain...

Страница 3: ...tem developed to transport animal meal or pelleted feed with a diameter of up to 5 mm and a length of 10 mm from a silo to a number of feeding locations in the pig barn The feed is transported in a ga...

Страница 4: ...on may start it without knowing that the system is being serviced Therefore do not dismantle the system or dismount screening lids and covers without cutting off and locking the main switch Never plac...

Страница 5: ...cts protruding from the walls or hanging down from the ceiling Ventilating plants posts or other piping that the feeding system passes The possibility of suspending supporting or in other ways fixing...

Страница 6: ...the system The return pipe on the other hand may be lead down vertically Z piping and two bends assembled at a right angle are to be avoided wherever possible This type of installation causes the tra...

Страница 7: ...Consequently the drive unit may be placed at the middle of the feeding system if other locations are not possible This type of installation however increases the risk of feed segregation and should t...

Страница 8: ...gs to adapt the height to the silo Mount the inspection pipe after the outlet pipe on the loading hopper using a splicing sleeve Place the inspection pipe so that the oblong hole is horizontal and cov...

Страница 9: ...he splicing sleeves Grind the pipes on the inside and the outside and remove any chips from the pipes before installation The feed pipes must be supported every 3 metres and attach to the ceiling wall...

Страница 10: ...on the corner wheel is incorrect too much resistance will build up in the system over time and the system may subsequently break down Without With Rotating direction When mounting the feed pipes make...

Страница 11: ...urn Sensor switch Place the sensor between the last feed outlet and the loading hopper however not closer than 1 5 metres from a bend The feed pipe must be supported immediately before or after the pl...

Страница 12: ...utter The wire has been wound into shape and will not unwind when cut Collect the wire It is important that all wire threads are intact and placed nicely in the wire collector and that there are no pl...

Страница 13: ...until the tightening wheel has travelled of its total to the right Indicate the place where the wire is to be shortened Cut the wire in a link without carrier and collect the chain using a joint link...

Страница 14: ...ch individual feed box allowing the feed to fall freely through the feed pipe To close lift the same lever and lock thus closing all feed dispensers The same principle is used for the automatic openin...

Страница 15: ...opening device Where several lines are used join the wire along the wall in front of the opening device Take care to apply uniform tension on each line Adjusting the opening device Set the opening dev...

Страница 16: ...365 87365 87360 10 Spline for axle gear 87367 87367 87367 87367 87368 11 Rear plate gear 87170 87170 87170 87170 87180 12 Bracket motor 13 Bracket gear 14 Axle bracket 15 Wire break switch 16 Holder f...

Страница 17: ...Page 17 09 11 2018 ACO FUNKI Tlf 97119600 www acofunki com FEEDING SYSTEM MASTER CHAIN...

Страница 18: ...855 Transmitter Receiver 88831 ICS R 001 TP 5 YELLOW 88830 ICS T O TP 5 RED Type With gate 84232 84242 84252 No Pipe 38 mm 50 mm 60 mm 1 Upper part loading hopper with gate 2 Gate 3 Inspection plate T...

Страница 19: ...Page 19 09 11 2018 ACO FUNKI Tlf 97119600 www acofunki com FEEDING SYSTEM MASTER CHAIN...

Страница 20: ...CHAIN FEEDING SYSTEM Opening motor No Type 88600 1 Gear motor 87485 2 Stop switch 87350 3 Bracket 88630 4 Axle 88645 5 Spline 8 x 7 88642 6 Protection plate 88660 7 Opening rod 88670 8 Bracket for st...

Страница 21: ...wear X Check plastic plates for wear X Check joint link for wear X Check chain tension Shorten if necessary X X Feed bends Check for jarring sounds scraping or wheezing sounds X X Open and clean feed...

Страница 22: ...ken Possible defects Impurity inside the system Wrong adjustment of loading hopper congestion Wrong adjustment of sensor switch or error in sensor switch The system stops after a short while Incorrect...

Страница 23: ...between the spindles should be reduced so that the V belts can be mounted loosely in the track of the V belt washers When the set of V belts has been mounted the tightness of the belts can be control...

Страница 24: ...09 11 2018 ACO FUNKI Tlf 97119600 www acofunki com Page 24 MASTER CHAIN FEEDING SYSTEM...

Отзывы: