Page 7
09-11-2018 · ACO FUNKI · Tlf. 97119600 · www.acofunki.com
FEEDING SYSTEM
MASTER CHAIN
®
Drive unit
The optimum location of the drive unit is between the last feed outlet and the loading hopper. See
rotating direction on the illustration.
The drive unit may be installed:
-
directly on the floor
-
4-20 cm above the floor on adjustable legs
-
on wall-mounted shelf brackets
Egebjerg’s drive unit has been designed to allow feed to pass through. Consequently, the drive unit
may be placed at the middle of the feeding system if other locations are not possible. This type of
installation, however, increases the risk of feed segregation, and should therefore be avoided
.
The drive unit works best when there is a long piece of straight piping before the drive unit inlet.
In chain systems there must be a straight piece of piping measuring at least 3 metres from the drive
unit inlet to the bend before it.
Sensor switch
Place the sensor switch after the last feed outlet. Place the sensor a minimum of 1.5 metres from the
nearest feed bend.
Min 3 meter.
Min. 1,5 meter.
Rotating direction