ELECTRICAL CONNECTIONS
IMPORTANT
- PLEASE DOUBLE CHECK AND MAKE SURE YOU HAVE THE
CORRECT POWER SOURCE BEING USED FOR THE SYSTEM PURCHASED.
FOR THE 12K BTU SYSTEM, IT WILL REQUIRE A SINGLE POLE 15-AMP BREAKER,
115 VOLTS
FOR THE 18K BTU SYSTEM, IT WILL REQUIRE A DOUBLE POLE 20-AMP BREAKER,
240 VOLTS
FOR THE 24K BTlcJ SYSTEM, IT WILL REQUIRE A DOUBLE POLE 30-AMP
BREAKER, 240 VOLTS
FOR THE 36K BTU SYSTEM, IT WILL REQUIRE A DOUBLE POLE 40-AMP BREAKER,
240 VOLTS
THE ELECTRICAL WIRING COVER ON THE OUTDOOR CONDENSER AND PLACE
OFF TO THE SllDE.
REMOVE THE TWO ROUND BLACK KNOCKOUTS FROM THE WIRING COVER
PLATE.
INSTALL THE WIRE WHIP FROM THE DISCONNECT BOX USING THE RIGHT
HAND KNOCKOUT.
*FOLLOW THE DIRECTIONS IN THE WIRING DIAGRAM PROVIDED ON THE
NEXT PAGE FOR YOUR SPECIFIED UNIT
INSTALL THE COMMUNICATIONS CABLE FROM THE INDOOR AIR HANDLER
USING LEFT-HAND KNOCKOUT.