Repeat step 18 at the outdoor condenser. line up the condenser connections
to the lineset fittings. hand tighten the first few threads and use the adjustable
wrenches to tighten down the rest. tighten unit all the threads can't be seen,
and the fittings are bottomed out together.
Locate the brass hexagonal valve caps just above the lineset connections. using
an adjustable wrench, remove the valve caps.
Insert a 5 mm allen key into the valve body assemblies. turn the valve body
counterclockwise to open the refrigerant valves. this will release the refrigerant
into the system.
IMPORTANT
- be sure to use two wrenches when
tightening the fittings, one to back up the condenser
connection, and one to screw the lineset side together.
this will prevent the copper from twisting and breaking
during installation.
IMPORTANT -
You will need to use a little bit of force to open the valve bodies
and start the threads. once the valve starts sp'inning, it will spin freely. keep
turning the valves counterclockwise unit you hit a good amount of resistance.
do not force further. now the valve body is completely open. do not close the
valve body after the refrigerant is released. it needs to stay open for proper
unit operation.
Re-install the brass hexagonal valve caps.
21.
22.
23.
24.