background image

Owner’s Manual & 
Installation Manual

ACIQ EZ CONNECT HEAT PUMP SYSTEM

COVERS MODELS

ACIQ-12W-EZ115/ACIQ-12Z-EZ115
ACIQ-18W-EZ230/ACIQ-18Z-EZ230
ACIQ-24W-EZ230/ACIQ-24Z-EZ230
ACIQ-36W-EZ230/ACIQ-36Z-EZ230

IMPORTANT NOTICE:

Read this manual carefully before 
installing or operating your new heat 
pump unit. Make sure to save this 
manual for future reference.

Содержание ACIQ-12W-EZ115

Страница 1: ...MODELS ACIQ 12W EZ115 ACIQ 12Z EZ115 ACIQ 18W EZ230 ACIQ 18Z EZ230 ACIQ 24W EZ230 ACIQ 24Z EZ230 ACIQ 36W EZ230 ACIQ 36Z EZ230 IMPORTANT NOTICE Read this manual carefully before installing or operating your new heat pump unit Make sure to save this manual for future reference ...

Страница 2: ... 45373 Phone 937 335 2626 Fax 937 339 2776 IMPORTANT NOTE Read this manual carefully before installing or operating your new heat pump unit Make sure to save this manual for future reference Please check the applicable models technical data and manufacturer information from the Owner s Manual ...

Страница 3: ...TABLE OF CONTENTS Title Page 02 Safety Precautions 03 Owners Manual Tools Required 07 Getting Started 08 Parts Included 09 Installation Manual Installation 11 Electrical Connections 16 Diagram 17 ...

Страница 4: ......

Страница 5: ......

Страница 6: ......

Страница 7: ...2 FT LEVEL 3 UTILITY KNIFE 4 2 PHILIPS SCREWDRIVER 5 5MM ALLEN KEY 6 NEEDLE NOSE PLIERS 7 STANDARD SET OF DRILL BITS 8 CORDED OR CORDLESS DRILL 9 3 5 HOLE SAW WITH ARBOR BIT 10 2 8 ADJUSTABLE WRENCHES 11 SPRAY BOTTLE FOR SOAPY WATER SOLUTION ...

Страница 8: ...utdoor unit and line set connections If caps are missing please stop and contact us immediately UNBOXING THE EQUIPMENT INDOOR SECTION When unboxing the indoor section make sure to check for any physical damage to the air handler Also make sure the connection cable is intact and physically connected to the air handler If the air handler section is damaged or the connection cable is disconnected mis...

Страница 9: ... Wall Anchors xS Used for securing the mounting plate of the indoor unit to the interior wall batteries x2 Used for powering Hand held Remote Controller Drain Joint Used to drain excess condensation water away from the outdoor condenser Foam insulation x2 Used for wrapping joints where the EZ Connect lineset will meet the indoor air handler factory piping connections Tar Tape x2 Used for wrapping ...

Страница 10: ...sed for connecting to the factory drain tubing to remove condensation from the indoor air handler Wall Sleeve Used for protecting the refrigerant lines communication cable and drain tubing as it is passed through the wall Beauty Cap Used for capping of the hole drilled for the refrigerant lines communication cable and drain tubing on the outside portion of the home UV Tape x3 Used for bundling the...

Страница 11: ...drain tubing bundle Remove the wall template Locate the metal wall bracket attached to the backside of the indoor air handler From the factory it is attached to the air handler with a sheet metal screw The screw is located near the center of the air handler Remove the screw and wall bracket from the air handler Using the included mounting hardware install the wall anchors and screw the wall bracke...

Страница 12: ...p section of the air handler on to the bracket first making sure to catch the clips on the wall bracket to the air handler itself Once the top clips are in place press down on the air handler to lock the bottom to the wall bracket IMPORTANT This may be difficult for a single person to manage If you have a helper available it would be best to have them help balance out the unit as the line bundle i...

Страница 13: ... one to back up the factory connection and one to screw the lineset side together this will prevent the copper from twisting and breaking during installation Set the outdoor condenser in place pick a location that has no airflow obstructions for the outdoor unit make sure no combustible materials will be within proximity of the unit IMPORTANT makes sure if the unit is being mounted to a wall brack...

Страница 14: ...will release the refrigerant into the system IMPORTANT be sure to use two wrenches when tightening the fittings one to back up the condenser connection and one to screw the lineset side together this will prevent the copper from twisting and breaking during installation IMPORTANT You will need to use a little bit of force to open the valve bodies and start the threads once the valve starts sp inni...

Страница 15: ...ss If bubbles form again a leak is present IMPORTANT If a leak is found and present the fittings will need to be re tightened down After re tightening the fittings repeat the leak check process again until no bubbles are present Wipe down all the soapy water solution off the fittings using a clean rag or paper towel Using the tar tape provided with the indoor air handler wrap the factory fittings ...

Страница 16: ...IRE A DOUBLE POLE 40 AMP BREAKER 240 VOLTS THE ELECTRICAL WIRING COVER ON THE OUTDOOR CONDENSER AND PLACE OFF TO THE SllDE REMOVE THE TWO ROUND BLACK KNOCKOUTS FROM THE WIRING COVER PLATE INSTALL THE WIRE WHIP FROM THE DISCONNECT BOX USING THE RIGHT HAND KNOCKOUT FOLLOW THE DIRECTIONS IN THE WIRING DIAGRAM PROVIDED ON THE NEXT PAGE FOR YOUR SPECIFIED UNIT INSTALL THE COMMUNICATIONS CABLE FROM THE ...

Страница 17: ...DIAGRAM FOR PREVIOUS PAGE ...

Отзывы: