DSIM-GI
Installation Guide Rev R
Page 9 of 20
LED Fault Conditions Blinking Patterns
LED Blinking Pattern
Indications
Steady on Pink
24 volt input into DSIM-GI module is out of the
operational range of 21.5 to 26.5 VDC. If this
occurs, check for correct AC voltage input to the
amplifier and for correct output DC voltage of
internal power supply to the RF module
Steady Repeating Orange Blinks
Temperature in DSIM-GI module is too high / low
(above 221ºF/105ºC or below -40ºF/-40ºC)
Quick Blue / Orange Blinks
Pilot Lost; DSIM-GI automatically switches to
Thermal (TGC) mode until Pilot channel is
restored
Note:
The DSIM-GI LED blinks after the pilot channel count will be orange during programming and blue
when in operation
.
7. DSIM Interface Cable Assembly
To make the connection from the DSIM controller to the DSIM-GI AGC module use cable
assembly P/N 240330-01 as shown below. Note: The RF module is shown with faceplate
cover removed for clarity.
Содержание DSIM-GI