P7280/P7270I/P7280 Refresh/P7270I Refresh
Confidential
3-3
No
Symptom
Procedure
3
No Image
- Ensure the Signal Cable and Source work
(If you connect multiple sources at the same time, use the
“Source” button swtich)
- Ensure all connectors are securely connected and aren’t
broken
- Check Main Board
- Check DMD Board
- Check I/O Board
- Check DMD Chip
- Check Engine Module
- Check Wireless Module and IP address (If you use WLAN or
LAN to transfer signal)
4
No Light On
- Ensure all connectors are securely connected and aren’t
broken
- Check Lamp Module
- Check Lamp Driver
- Check LVPS
- Check Main Board
5
Machanical Noise
- Check Color Wheel
- Check Fan Module
6
Line Bar/Line Defect
- Check if the Main Board and the DMD Board are
assembled properly
- Check Main Board
- Check DMD Board
- Check DMD Chip
Содержание P7270I Refresh
Страница 19: ...P7280 P7270I P7280 Refresh P7270I Refresh Confidential 1 12 Remote Control Layout ...
Страница 24: ...P7280 P7270I P7280 Refresh P7270I Refresh Confidential 1 17 System Block Diagram ...
Страница 130: ...P7280 P7270I P7280 Refresh P7270i Refresh Confidential 1 Appendix A DC P7270I P7270I Refresh 2 7 7 8 5 3 8 4 7 6 1 ...
Страница 131: ...P7280 P7270I P7280 Refresh P7270I Refresh Confidential 2 DC P7270I P7270I Refresh 12 7 7 13 18 17 15 14 11 16 10 9 7 7 ...
Страница 132: ...P7280 P7270I P7280 Refresh P7270I Refresh Confidential 3 DC P7270I P7270I Refresh 24 23 21 22 16 19 16 20 7 26 25 27 28 ...
Страница 151: ...P7280 P7270I P7280 Refresh P7270I Refresh Confidential 22 SUB ASSY TOP SHIELDING MODULE P7270I P7270I Refresh ...
Страница 153: ...P7280 P7270I P7280 Refresh P7270I Refresh Confidential 24 ASSY PCBA MODULE P7270I P7270I Refresh ...
Страница 158: ...P7280 P7270I P7280 Refresh P7270I Refresh Confidential 29 ASSY COLOR WHEEL MODULE P7270I P7270I Refresh ...