Chapter 1 Overview of the WMS100 Subsystem
1.1
Overview Features
The Acer | HDS Workgroup Modular Storage WMS100 subsystem (hereafter referred to as the
WMS100) is available in two models: the floor model and the rack-mount model.
There are two types of the WMS100 floor model. The first type is a combination of the
DF700-RKXS (hereafter referred to as the RKXS) and the floor standing kit DF-F700-H1J
(hereafter referred to as the Floor [RKXS+H1J] Model). The second type is a combination of
the RKXS, the DF700-RKAJAT (hereafter referred to as RKAJAT), and the floor standing kit
DF-F700-H2J (hereafter referred to as the Floor [RKXS+H2J] Model).
The WMS100 rack-mount model is a subsystem that combines the RKXS, the RKAJAT, and the
DF700-RKNAS2G (hereafter referred to as RKNAS). For information regarding model types,
see sections 1.2 and 1.3.
The following WMS100 subsystem features are discussed in this section:
High Data Availability.
Connectivity.
Scalability.
Performance Reporting and Monitoring.
Reliability, Availability, and Serviceability.
1.1.1
High Data Availability
The Acer | HDS WMS100 is designed for high performance and protection of user data. See
section 1.2 for additional information on the reliability and availability features of the Acer
| HDS WMS100 subsystem.
1.1.2
Connectivity
The Acer | HDS WMS100 subsystem provides connectivity to most open systems through a
standard Fibre Channel interface or Network interfaces. The following paragraphs describe
the features of Fibre Channel and Ethernet:
High-Speed Data Transfer
Fibre Channel: When using the Fibre Channel interface for host interface, the WMS100
subsystem can transfer data between the host computer and the WMS100 at a maximum
speed of 200 MB/sec. Throughput can be accessed by connecting multiple devices
through the Fibre Channel, even when accessing from multiple hosts to the WMS100.
Ethernet: With the 1 G bps Ethernet connection, the subsystem can transfer data
between host computer and the subsystem at a maximum speed of 100 M bytes/s per
port via a network. Enough throughput can be got even when having multiple access to
the multiple devices connected to the same network loop.
Содержание HDS WMS100
Страница 1: ...MK 95DF738 01 Acer HDS WMS100 User and Reference Guide ...
Страница 2: ......
Страница 8: ...viii Preface ...
Страница 12: ...xii Preface ...
Страница 22: ...xxii Contents ...
Страница 40: ...18 Chapter 2 Planning for Installation and Operation Figure 2 1 Position of Labels on Floor Model RKXS H1J ...
Страница 41: ...Acer HDS WMS100 User and Reference Guide 19 Figure 2 2 Position of Labels on Floor Model RKXS RKAJAT H2J ...
Страница 42: ...20 Chapter 2 Planning for Installation and Operation Figure 2 3 Position of Labels on Rack Mount Model RKXS ...
Страница 43: ...Acer HDS WMS100 User and Reference Guide 21 Figure 2 4 Position of Labels on Rack Mount Model RKNAS ...
Страница 44: ...22 Chapter 2 Planning for Installation and Operation Figure 2 5 Position of Labels on Rack Mount Model RKAJAT ...
Страница 56: ...34 Chapter 2 Planning for Installation and Operation ...
Страница 64: ...42 Chapter 3 Powering On Off Procedure ...
Страница 132: ...110 Chapter 7 Configuring Storage on the Thunder 9530 V Series Subsystem Figure 7 1 Fibre Channel Setting ...
Страница 139: ...Acer HDS WMS100 User and Reference Guide 117 Figure 7 3 Logical Status Tab NAS Figure 7 4 RAID Group Dialog Box ...
Страница 146: ...124 Chapter 7 Configuring Storage on the Thunder 9530 V Series Subsystem When a formatted logical unit exists Ð Ð Ð ...
Страница 157: ...Acer HDS WMS100 User and Reference Guide 135 The mapping information is updated and the following window displays ...
Страница 188: ...166 Chapter 7 Configuring Storage on the Thunder 9530 V Series Subsystem Ð ...
Страница 192: ...170 Chapter 7 Configuring Storage on the Thunder 9530 V Series Subsystem ...
Страница 213: ...Acer HDS WMS100 User and Reference Guide 191 Figure 8 7 NNC Information Screen ...
Страница 222: ...200 Chapter 8 Troubleshooting 4 Clear specified factors of NNC partial alarm 5 Click the Recovery button ...
Страница 252: ...230 Chapter 8 Troubleshooting ...
Страница 270: ...248 Appendix B System Parameter Settings List ...
Страница 316: ...294 Appendix F List of Storage Capacities Corresponding to RAID Levels and Configurations ...
Страница 320: ...298 Appendix G Port Address Mapping Table ...
Страница 326: ...304 Appendix I Number of Logical Blocks ...