16
Chapter 3
Power supply specifications
Specifications
Value
Input voltage
specifications
Rated input voltage
100 VAC to 240 VAC
Input specifications
Rated input line
85 VAC to 264 VAC
Frequency range
50 to 60 Hz
Rated input power
@ 100 V input, Rated input power = 1100 W
@ 230 V input, Rated input power = 1400 W
Rated input current
14A @100VAC
6A @240VAC
Steady state power
1400W (@240VAC)
BTU rating
BTU/hr 3753.2
BTU/hr@100~140VAC
4776.8 BTU/hr@180~240VAC
Ambient temperature
range
Operating
10° to 35° C (50° to 95° F)
Non-operating
-40° to 70° C (-40° to 158° F)
Relative humidity
(non-condensing)
Operating
8% to 90% (non-condensing)
Non-operating
5% to 95% (non-condensing)
Dielectric voltage
withstand
Input to output
3000 VAC/minute
Input to ground
500 VAC/minute
Maximum wet bulb
temperature
106.3° F (41.3° C)