SP8016-1005
ACCU-STEAM SERVICE MANUAL
PAGE 12
IGNITION MODULE
Is the electronic device that verifies that the griddle has ignited and is running. If the proper
signals are not received from the flame sense it will lockout the griddle.
Unplug the unit.
1.
Remove the three screws from the front door panel and drop the panel down.
2.
Disconnect the ignition cable, molex connector for the wire harness and the mounting screws.
3.
Apply silicone dielectric grease to the connections.
Reassemble in reverse order.
4.
Note: Serial numbers 7184 and above will have an Interim Intermittent Ignition system in
conjunction with the dual solenoid valve. The main gas valve was removed
MAIN BURNERS
Main burners are a ceramic burner that supplies the required heat to operate the griddle. If the
get wet they should be allowed to dry without applying heat as they will crack and will need
replaced
Unplug the unit and disconnect the gas and let the unit cool.
1.
Remove the retaining nut from the gas supply elbow.
2.
Remove the four retaining nuts from burner box flange and drop the box down.
3.
Clean the orifices.
4.
Reassemble in reverse order and run the unit up to 400 degrees.
5.
36”& 48” MODEL BURNER
AT2B-2991-1
BURNER 24” MODEL
AT2B-2131-1
IGNITION MODULE
AT2E-1807-1
REMOVAL AND INSTALLATION