SP8016-1005
ACCU-STEAM SERVICE MANUAL
PAGE 11
STANDBy BURNER (PILOT BURNER)
This device is a small ceramic burned used to ignite the main burners. It also has the ignition probe
and flame sense probe. Improper installation can cause the griddle not ignite or intermittently
shutdown
Unplug the unit and shut off the gas supply and let the unit cool.
1.
Loosen the hose clamp on the venturi.
2.
Loosen the two nuts that hold the burner spacer and step bracket.
3.
Remove the two nuts on the studs that hold the ignitor sensor bracket.
4.
Remove the ignitor cable from the ignitor probe. Inspect for damage.
5.
Pull the orifice adaptor out of the venturi and pull the pilot assembly down.
6.
Note: Check the ignitor probes and ground plane assembly for discoloration or oxidation and
replace as needed. Also check for proper gapping. See illustration below.
Remove the orifice adaptor from the compression elbow and clean.
7.
Reinstall in reverse order.
8.
Note: Make sure that the hose clamp does not block the venturi opening.
See Pages XX to XX for instructions on measuring flame sense.
PROBES
IGNITOR & FLAMES SENSE SETTING
STANDBy BURNER
AT2A-2255-2
IGNITOR KIT
REMOVAL AND INSTALLATION