ACCU-STEAM  SERVICE MANUAL

PAGE 8

RTD ThERMOSTAT CALIBRATION

The operating temperature range is 200 °F to 400 degrees F. Record the measured griddle surface 

temperature at the set points of 200 °F, 300 °F and 400 °F to determine if the controller is out of 

range. The calibration offset potentiometer shifts the range up or down but range or gain width is fixed 

and cannot be adjusted. If the controller is 

± 

10 °F out of range, replace it.

Open the control panel

1. 

Plug the unit in and hook up the gas supply.

2. 

Place a weighted temperature probe on the cooking surface of the griddle in a location above 

3. 

the griddle temperature sensor. Keep the probe off of the dimples and use a small amount of 

high temperature cooking oil between the surface of the probe and giddle.

Set the thermostat at 200 °F, turn the unit on and allow the temperature to stabilize. Take a 

4. 

reading from the thermometer and record the value.

Set the thermostat at 300 °F, allow to stabilize and record the value.

5. 

Set the thermostat at 400 °F, allow to stabilize and record the value.

6. 

Take a reading from the thermometer. The value should be 400 °F (+1 °F / -4 °F).If not, adjust 

7. 

the offset potentiometer on the thermostat and allow the unit to stabilize.

Repeat step 7 as is necessary.

8. 

Close the control panel, install the retaining screws and allow the unit to stabilize.

9. 

 Observe the thermometer. The indicator reading should be 400 degrees F (+1 °F / -4 °F). If 

10. 

the reading is not, open the panel and repeat steps 7 – 9.

TEMP PROBE

The temperature sensor is screwed into a thermal-well underneath the griddle chamber. It is 

isolated from the distilled water of the griddle chamber. It is designed to indicate temperature 

by changing the resistance based on temperature to the thermostat. Be careful if you have to 

drill out the sensor not to puncture the chamber as it will render the griddle un-repairable.

Unplug the unit.

1. 

Remove the three screws from the front door panel and drop the panel down.

2. 

On the bottom side of the unit, locate the thermal-well that the probe capillary is screwed into 

3. 

and remove. 

Remove the leads from pins 6 & 7 on the thermostat.

4. 

Reinstall in reverse order. (Type K probe, yellow on #6 and red on #7)

5. 

PROBE LOCATION 

UNDERSIDE OF GRIDDLE 

RTD TEMPERATURE SENSOR      

AT0E-2885-3

REMOVAL AND INSTALLATION

Содержание 2611

Страница 1: ...SP8016 1005 ACCU STEAM SERVICE MANUAL SERVICE MANUAL SERIAL NUMBERS 2611 AND UP NATURAL GAS AND PROPANE...

Страница 2: ...SP8016 1005 ACCU STEAM SERVICE MANUAL Toll Free 800 480 0415 Office 260 469 3040 Fax 260 493 8914 email service accutemp net Web Site www accutemp net Technical Services...

Страница 3: ...DELAY RELAY 9 REMOVAL AND INSTALLATION HI LIMIT ASSEMBLY 9 10 REMOVAL AND INSTALLATION STANDBY BURNER PILOT 11 REMOVAL AND INSTALLATION MAIN BURNERS 12 REMOVAL AND INSTALLATION IGNITION MODULE 12 REM...

Страница 4: ...SP8016 1005 ACCU STEAM SERVICE MANUAL PAGE 2 Document history Current revision Date Prior revision Date Change 1005 5 14 10 N A N A Initial release of manual...

Страница 5: ...rning food in place SEQUENCE OF OPERATION S N 2611 to 7183 120V power is supplied to the primary side of the transformer 24VAC comes off the secondary side of the transformer which provides power to t...

Страница 6: ...should be set at 5 and the stand by burner should be set at 3 5 inches of water column for natural gas when the griddle is in operation For propane units the pilot should be set at 8 inches and the m...

Страница 7: ...rature setting three reading across the back three across the middle and three across the front All readings should be within 3 degrees Check for hot spots or leaks Notify Accutemp Service with any fl...

Страница 8: ...at0e 1800 1 ON OFF SWITCH AND CONTACTS This switch consists of 4 parts and each can be changed individually if any of the parts failed Unplug the unit 1 Remove the three screws from the front door pan...

Страница 9: ...everse order 5 Note Units with serial numbers 2611 to 7550 have a type K thermostat and thermocouple red and yellow leads Serial numbers 7551 and above have a RTD thermostat and probe two red leads Wh...

Страница 10: ...cord the value 6 Take a reading from the thermometer The value should be 400 F 1 F 4 F If not adjust 7 the offset potentiometer on the thermostat and allow the unit to stabilize Repeat step 7 as is ne...

Страница 11: ...ch bracket Note It is extremely important that the solder washer has good surface contact with the surface of the thermal well Make sure the solder washer is installed before the flat washer Reattach...

Страница 12: ...SP8016 1005 ACCU STEAM SERVICE MANUAL PAGE 10 REMOVAL AND INSTALLATION...

Страница 13: ...studs that hold the ignitor sensor bracket 4 Remove the ignitor cable from the ignitor probe Inspect for damage 5 Pull the orifice adaptor out of the venturi and pull the pilot assembly down 6 Note Ch...

Страница 14: ...bove will have an Interim Intermittent Ignition system in conjunction with the dual solenoid valve The main gas valve was removed MAIN BURNERS Main burners are a ceramic burner that supplies the requi...

Страница 15: ...der 5 REMOVAL AND INSTALLATION OLD STYLE VALVE TRAIN S N 2661 TO 7894 NEW STYLE VALVE TRAIN S N 7895 UP Control Valve and Pilot Valve gas pressures must be adjusted after replacing to assure to assist...

Страница 16: ...To check micro amps disconnect the orange wire from the flame rod connect the amp meter in series with the flame sensing rod terminal and the orange wire from the wiring harness b An Accutemp volt me...

Страница 17: ...icroamps or a fluctuating reading that won t stabilize The possible causes for each type of reading are a 0 millivolts or micro amps Look for an open or grounded sensor wire or flame rod or a defectiv...

Страница 18: ...thermostat setting to 300 F allow griddle to cycle through two heat cycles 5 Place weighted temperature probe and record temperatures according to the chart below 6 Temperatures shall be within 7 5 F...

Страница 19: ...2 3 705 3 728 3 751 3 774 3 797 3 82 200 3 82 3 843 3 866 3 889 3 912 3 935 3 958 3 981 4 004 4 027 4 05 210 4 05 4 073 4 096 4 119 4 142 4 165 4 188 4 211 4 234 4 257 4 28 220 4 28 4 303 4 326 4 349...

Страница 20: ...64 74 53 59 48 56 50 56 HEAT VALUE NATURAL GAS 1000 PROPANE GAS 2300 PILOT BURNER 24 GRIDDLE MAIN BURNER 36 GRIDDLE MAIN BURNER 48 GRIDDLE MAIN BURNER Altitude ft NG LP NG LP NG LP NG LP 3000 59 71 4...

Страница 21: ...5 72 54 58 47 55 47 1 25MM 9000 65 72 54 59 48 1 25MM 48 3 64 10000 66 72 54 59 49 1 25MM 49 3 64 HEAT VALUE NATURAL GAS 1300 PROPANE GAS 2700 PILOT BURNER 24 GRIDDLE MAIN BURNER 36 GRIDDLE MAIN BURNE...

Страница 22: ...RED RED BLU RED K TYPE YEL RED 1 2 3 4 5 6 7 PWR NA COM OUTPUT K TYPE CONTROLLER CAL OFFSET ADJ t o HEAT LT2 PWR LT1 WHT RED RED RED ORN ORN or YEL GRN GRN BURNER 1 2 3 4 5 6 24V SEC 120V PRI MAIN GA...

Страница 23: ...RED 1 P1 2 1 J1 2 OFF ON RED RED BLU RED HEAT LT 2 PWR LT1 WHT YEL YEL ORN ORN or YEL GRN GRN BURNER 1 2 3 4 5 6 24V SEC 120V PRI MAIN GAS CONTROL VALVE MAIN BURNER VALVE SPARK MODULE HV IGNITOR SENSO...

Страница 24: ...2 1 J1 2 OFF ON RED BLU RED RED RED 1 3 5 6 8 9 L1 L2 OUTPUT PRTD PRTD TYPE CONTROLLER CAL OFFSET ADJ t o HEAT LT 2 PWR LT 1 WHT RED ORN YEL 24V SEC 120V PRI MAIN GAS CONTROL VALVE MAIN BURNER VALVE Y...

Страница 25: ...SP8016 1005 ACCU STEAM SERVICE MANUAL...

Отзывы: