background image

 

Manual Part # 800-1403-001 Revision 06-01-2020

 

Page 15 of 16

 

Popular ProScale Products 

 

 

ProStop 

is a complete Digital Stop and Fence System for 

miter and chop saws. It includes an aluminum Fence, a 
Flip-Stop with fine adjust, double locking mechanism, and 
Quick-Sets. Many add-on plates available too! 
 
 

ProPanel

 is a GIANT DIGITAL CALIPER used to make 

inside, outside, diagonal, hole-edge and hole-hole 
dimensional measurements. 
This is a rugged linear measuring tool designed to make 
"on the manufacturing floor" measurements.

 

 
 

ProKit 590

 is an ideal foundation for a 'build-it-yourself" 

dimensional measuring system.  ProKit 590 is available in 
measuring lengths up to 190 inches (4.8m). SPC output 
comes standard. Wireless data transmitter is available.

 

 

ProTable-SA 

is a self-contained, single axis measuring 

table/QC station. Leg sets and casters make this product 
easy to move around the manufacturing floor. Temperature 
compensation and non-linear error correction are built into 
the readout. Systems are available up to 24 ft. long. 
Accuracy /- .003 inches over the entire range. SPC 
output and temperature compensation are included. 
Custom configurations are available in one or two-axis 
versions. 

 
 

ProTable-CAB

 is a two-axis measuring system designed for 

quick and affordable length and width measurements of 
cabinet doors or other panel type products. Can be built with 
angle and out-of-square measurements too. 

 

 

 

Содержание ProScale 950 Series

Страница 1: ...with C even more features 950 Series Readout 700 1600 M50 10pin input connector Note This guide applies to ProScale readouts with Firmware Version 4 000 firmware version is displayed on power up If y...

Страница 2: ...Pr2 Reading Direction __________________ Parameter Pr13 Linear Multiplier __________________ Parameter Pr14 Compatibility __________________ If your digital scale has this pattern set Parameter 14 to...

Страница 3: ...These Readouts may be mounted several ways 1 Using Velcro or double sided tape 2 Use the 3 punch out holes inside case Mount readout to machine panel using 6 or M4 flathead screws 3 Use any or all of...

Страница 4: ...e upper right and lower left corners of the readout Lift the cover off Remove the old battery and install a new battery noting the proper orientation Replace the cover and screws External Power These...

Страница 5: ...increased or decreased c If the displayed value got larger smaller and this IS correct for your installation no further steps are needed d If the displayed value got larger smaller and this IS NOT cor...

Страница 6: ...What happens if a KEY IS HELD DOWN Key Action ON OFF Nothing UNITS Nothing PLUS The displayed value increases faster each 2 seconds DATUM After 4 seconds the battery voltage is displayed After 7 secon...

Страница 7: ...s readout back to ABS mode SEND The currently displayed value is sent to the SPC port None F1 An offset value is applied If offset feature is enabled in the programming menu Also used to store compens...

Страница 8: ...LUS MINUS or DATUM keys are pressed See page 6 for key combination to turn this off The readout s display is frozen When this feature is enabled press F4 key to turn on off Monitor mode drift alarm is...

Страница 9: ...readout will show 5 5 16 and turn on the 200 indicator Minus sign Turns on when a negative value is displayed Battery level indicator When all 3 bars are lit your battery is good When only bottom bar...

Страница 10: ...o add functionality These include Mode feature Function Offsets Allows the readout to track up to 5 reference positions at the same time Monitor Allows the readout to watch for unintended motion drift...

Страница 11: ...on then Pr1 3 Release the UNITS key 4 After a moment the value for Pr1 will display Change the parameter value using the PLUS or MINUS keys Default the parameter value using the DATUM key Advance to...

Страница 12: ...ue 0 000 Pr29 Upper limit value 5 000 inches Pr30 Offset additions to use 0 None Pr31 First offset value 0 5000 inches Pr32 Second offset value 2 0000 inches Pr33 Third offset value 3 0000 inches Pr34...

Страница 13: ...eds to be replaced immediately Check programming values after new battery is installed LOCK The keypad is LOCKed but an attempt was made to change the calibration Unlock keypad to fix see page 6 P LOC...

Страница 14: ...readout Switching power supply Part number 550 2003 001 Provides 15VDC power to the readout Wireless Data Transmitter Part number 700 1037 001 Transmits measurement values to a remote computer using Z...

Страница 15: ...stem ProKit 590 is available in measuring lengths up to 190 inches 4 8m SPC output comes standard Wireless data transmitter is available ProTable SA is a self contained single axis measuring table QC...

Страница 16: ...ProScale LCD Readouts version 4 Page 16 of 16 Thank you for choosing a ProScale Product IT WAS PROUDLY MADE IN THE USA Accurate Technology Inc 270 Rutledge Rd Unit E Fletcher NC 28732 USA 1 828 654 7...

Отзывы: