background image

 

Manual Part # 800-1403-001 Revision 06-01-2020

 

Page 5 of 16

 

Initial Setup: 

 
Follow these steps to configure your readout for initial use: 
 

1.  When the readout is first powered on, it may show a 

No Enc

 message. 

This means there is not an encoder connected to the readout. To clear 
the message, connect a compatible encoder. 

 

2.  When an encoder is first connected, the readout may show 

No Pos

This informs the user that a position has not been programmed yet. For 
the initial setup, use the DATUM, and PLUS keys to set a 

POSITIVE

 

starting value. (Any POSITIVE value will work for now.) 

 

3.  Choose the units that will be initially used (millimeters, inches, or 

fractions). Each press of the UNITS key will change the units that are 
displayed. (The screen will show the units description each time the 
UNITS key is pressed.) 

 

4.  Check the reading direction: 

a)  With the readout showing a POSITIVE number on the screen, 

move the encoder system a short distance. 

b)  Take note if the displayed value increased or decreased. 
c)  If the displayed value got larger/smaller, and this 

IS

 correct for your 

installation, no further steps are needed. 

d)  If the displayed value got larger/smaller, and this 

IS NOT

 correct for 

your installation, the reading direction needs to be reversed. This 
can be accomplished two ways: 

i. 

If your encoder system is a Model 19, 29, 190, 290, 390, or 
590 type, you can rotate the encoder 180 degrees on the 
scale. 

ii. 

If the encoder cannot be rotated, or if the encoder is a 
Model 150 or Model 250 system, the reading direction 
must be reversed using the programming mode, parameter 
Pr2. Consult the Complete User Guide at 

www.proscale.com 

or contact factory for assistance with 

this. 
 

5.  Calibrate the readout. Since there are many thousands of applications 

for ProScale systems, all calibration methods cannot be described 
here. However, the general steps are the same. 

a.  Determine what value the readout should be showing. 
b.  Use the DATUM, PLUS, and MINUS keys to adjust the reading 

on the screen to match desired value. NOTE: To rapidly adjust 
the value, press and hold the PLUS or MINUS key down. (The 
update speed will increase every 2 seconds the key is held.) 

 

 

Содержание ProScale 950 Series

Страница 1: ...with C even more features 950 Series Readout 700 1600 M50 10pin input connector Note This guide applies to ProScale readouts with Firmware Version 4 000 firmware version is displayed on power up If y...

Страница 2: ...Pr2 Reading Direction __________________ Parameter Pr13 Linear Multiplier __________________ Parameter Pr14 Compatibility __________________ If your digital scale has this pattern set Parameter 14 to...

Страница 3: ...These Readouts may be mounted several ways 1 Using Velcro or double sided tape 2 Use the 3 punch out holes inside case Mount readout to machine panel using 6 or M4 flathead screws 3 Use any or all of...

Страница 4: ...e upper right and lower left corners of the readout Lift the cover off Remove the old battery and install a new battery noting the proper orientation Replace the cover and screws External Power These...

Страница 5: ...increased or decreased c If the displayed value got larger smaller and this IS correct for your installation no further steps are needed d If the displayed value got larger smaller and this IS NOT cor...

Страница 6: ...What happens if a KEY IS HELD DOWN Key Action ON OFF Nothing UNITS Nothing PLUS The displayed value increases faster each 2 seconds DATUM After 4 seconds the battery voltage is displayed After 7 secon...

Страница 7: ...s readout back to ABS mode SEND The currently displayed value is sent to the SPC port None F1 An offset value is applied If offset feature is enabled in the programming menu Also used to store compens...

Страница 8: ...LUS MINUS or DATUM keys are pressed See page 6 for key combination to turn this off The readout s display is frozen When this feature is enabled press F4 key to turn on off Monitor mode drift alarm is...

Страница 9: ...readout will show 5 5 16 and turn on the 200 indicator Minus sign Turns on when a negative value is displayed Battery level indicator When all 3 bars are lit your battery is good When only bottom bar...

Страница 10: ...o add functionality These include Mode feature Function Offsets Allows the readout to track up to 5 reference positions at the same time Monitor Allows the readout to watch for unintended motion drift...

Страница 11: ...on then Pr1 3 Release the UNITS key 4 After a moment the value for Pr1 will display Change the parameter value using the PLUS or MINUS keys Default the parameter value using the DATUM key Advance to...

Страница 12: ...ue 0 000 Pr29 Upper limit value 5 000 inches Pr30 Offset additions to use 0 None Pr31 First offset value 0 5000 inches Pr32 Second offset value 2 0000 inches Pr33 Third offset value 3 0000 inches Pr34...

Страница 13: ...eds to be replaced immediately Check programming values after new battery is installed LOCK The keypad is LOCKed but an attempt was made to change the calibration Unlock keypad to fix see page 6 P LOC...