background image

 

Operation Manual for ProScale LCD Readouts, version 4

 

Page 10 of 16

 

Additional Information: 

 

Consult the Complete User Guide a

www.proscale.com

 or contact factory for 

assistance with any of these more advanced functions: 
 

SPC PORT:

 Position data can be requested by external 

devices, or sent from readouts equipped with a SEND key. 
 
 
 

INPUT AND OUTPUT:

  

 
 
 
The third terminal on this strip allows for external devices (such as 
pushbuttons) to act as any key on the readout. Alternatively, this terminal can 
be used as an output control for limits, position monitor alarm, or Go/NoGo 
features. 

 
 
SPECIAL MODES:

 Your readout has several special modes/features that can 

be enabled to add functionality. These include: 
 

Mode/feature 

Function 

Offsets 

Allows the readout to track up to 5 reference 
positions at the same time. 

Monitor 

Allows the readout to watch for unintended 
motion/drift. 

Hold 

Allows the readout to freeze the screen 
temporarily. 

Go, NoGo 

Allows the readout to act as a Go, NoGo gage 
(up to 32 positions can be stored). 

Limits 

Allows readout to alert operator if position moves 
outside a preset zone. 

Input device mapping 

Controls how a pushbutton or footswitch works 
with the readout. 

Output controls 

Choose how the output of the readout works. 

Compensation 

Linear, Temperature, and Non-Linear 
compensation can be used to increase accuracy. 

Programming Mode 

Where you customize several dozen parameters 
to get the readout working exactly as you need. 

 

Note: Some of the above features are not available on every readout model. 

 

 

Input / Output 

Содержание ProScale 950 Series

Страница 1: ...with C even more features 950 Series Readout 700 1600 M50 10pin input connector Note This guide applies to ProScale readouts with Firmware Version 4 000 firmware version is displayed on power up If y...

Страница 2: ...Pr2 Reading Direction __________________ Parameter Pr13 Linear Multiplier __________________ Parameter Pr14 Compatibility __________________ If your digital scale has this pattern set Parameter 14 to...

Страница 3: ...These Readouts may be mounted several ways 1 Using Velcro or double sided tape 2 Use the 3 punch out holes inside case Mount readout to machine panel using 6 or M4 flathead screws 3 Use any or all of...

Страница 4: ...e upper right and lower left corners of the readout Lift the cover off Remove the old battery and install a new battery noting the proper orientation Replace the cover and screws External Power These...

Страница 5: ...increased or decreased c If the displayed value got larger smaller and this IS correct for your installation no further steps are needed d If the displayed value got larger smaller and this IS NOT cor...

Страница 6: ...What happens if a KEY IS HELD DOWN Key Action ON OFF Nothing UNITS Nothing PLUS The displayed value increases faster each 2 seconds DATUM After 4 seconds the battery voltage is displayed After 7 secon...

Страница 7: ...s readout back to ABS mode SEND The currently displayed value is sent to the SPC port None F1 An offset value is applied If offset feature is enabled in the programming menu Also used to store compens...

Страница 8: ...LUS MINUS or DATUM keys are pressed See page 6 for key combination to turn this off The readout s display is frozen When this feature is enabled press F4 key to turn on off Monitor mode drift alarm is...

Страница 9: ...readout will show 5 5 16 and turn on the 200 indicator Minus sign Turns on when a negative value is displayed Battery level indicator When all 3 bars are lit your battery is good When only bottom bar...

Страница 10: ...o add functionality These include Mode feature Function Offsets Allows the readout to track up to 5 reference positions at the same time Monitor Allows the readout to watch for unintended motion drift...

Страница 11: ...on then Pr1 3 Release the UNITS key 4 After a moment the value for Pr1 will display Change the parameter value using the PLUS or MINUS keys Default the parameter value using the DATUM key Advance to...

Страница 12: ...ue 0 000 Pr29 Upper limit value 5 000 inches Pr30 Offset additions to use 0 None Pr31 First offset value 0 5000 inches Pr32 Second offset value 2 0000 inches Pr33 Third offset value 3 0000 inches Pr34...

Страница 13: ...eds to be replaced immediately Check programming values after new battery is installed LOCK The keypad is LOCKed but an attempt was made to change the calibration Unlock keypad to fix see page 6 P LOC...

Страница 14: ...readout Switching power supply Part number 550 2003 001 Provides 15VDC power to the readout Wireless Data Transmitter Part number 700 1037 001 Transmits measurement values to a remote computer using Z...

Страница 15: ...stem ProKit 590 is available in measuring lengths up to 190 inches 4 8m SPC output comes standard Wireless data transmitter is available ProTable SA is a self contained single axis measuring table QC...

Страница 16: ...ProScale LCD Readouts version 4 Page 16 of 16 Thank you for choosing a ProScale Product IT WAS PROUDLY MADE IN THE USA Accurate Technology Inc 270 Rutledge Rd Unit E Fletcher NC 28732 USA 1 828 654 7...

Отзывы: