Programming Mode: 

 
Many features of the readout can be customized, plus additional tools can be 
configured using the programming menu. Consult the Complete User Guide at 

www.proscale.com

 

for more information about accessing, changing, and 

saving customized settings. 
 
Before making changes, open the readout case and verify the programming 
menu is accessible. The jumper to the left of the battery has three pins. Ensure 
pins 1 and 2 are connected with a shunt before proceeding. (After making 
changes, you can move the shunt to pins 2 and 3 to prevent further 
programming changes.) 
 
To start the programming menu, turn on the readout. 

1.  Press and hold the UNITS key. 
2.  Quickly press and release DATUM key. You will see 

PG on, 

then

 Pr1

.  

3.  Release the UNITS key.  
4.  After a moment, the value for Pr1 will display. 

 

 

Change the parameter value using the PLUS or MINUS keys. 

 

Default the parameter value using the DATUM key. 

 

Advance to next parameter by pressing the UNITS key. 

 

Exit programming menu following steps 1-3 above (OR wait 30 
seconds). Note: Changes made are immediately active. 

 

Parameter 
number 

What it does 

Default value 

Pr1 

Sets the value that is displayed when 
DATUM key is pressed. 

0.000 

Pr2 

0 = numbers increase when encoder 
moves right 
1 = numbers decrease when encoder 
moves right 

Pr3 

0 = PLUS, MINUS, and DATUM keys 
are operative 
1 = These keys are locked out.  

Pr4 

Value controls the resolution for 
decimals. 

Pr5 

How much motion is needed to wake 
up the readout. 

0.004 inches 

Pr6 

Controls if fractions round up or down. 

0 (round down) 

Pr7 

Controls resolution of 4

th

 decimal place 

(in inches) 

1 (

.0005” 

resolution) 

Pr11 

Controls which units modes appear. 

0 (All units) 

Pr12 

Auto-off timer (in minutes) 

15 

Содержание ProScale 950 Series

Страница 1: ...with C even more features 950 Series Readout 700 1600 M50 10pin input connector Note This guide applies to ProScale readouts with Firmware Version 4 000 firmware version is displayed on power up If y...

Страница 2: ...Pr2 Reading Direction __________________ Parameter Pr13 Linear Multiplier __________________ Parameter Pr14 Compatibility __________________ If your digital scale has this pattern set Parameter 14 to...

Страница 3: ...These Readouts may be mounted several ways 1 Using Velcro or double sided tape 2 Use the 3 punch out holes inside case Mount readout to machine panel using 6 or M4 flathead screws 3 Use any or all of...

Страница 4: ...e upper right and lower left corners of the readout Lift the cover off Remove the old battery and install a new battery noting the proper orientation Replace the cover and screws External Power These...

Страница 5: ...increased or decreased c If the displayed value got larger smaller and this IS correct for your installation no further steps are needed d If the displayed value got larger smaller and this IS NOT cor...

Страница 6: ...What happens if a KEY IS HELD DOWN Key Action ON OFF Nothing UNITS Nothing PLUS The displayed value increases faster each 2 seconds DATUM After 4 seconds the battery voltage is displayed After 7 secon...

Страница 7: ...s readout back to ABS mode SEND The currently displayed value is sent to the SPC port None F1 An offset value is applied If offset feature is enabled in the programming menu Also used to store compens...

Страница 8: ...LUS MINUS or DATUM keys are pressed See page 6 for key combination to turn this off The readout s display is frozen When this feature is enabled press F4 key to turn on off Monitor mode drift alarm is...

Страница 9: ...readout will show 5 5 16 and turn on the 200 indicator Minus sign Turns on when a negative value is displayed Battery level indicator When all 3 bars are lit your battery is good When only bottom bar...

Страница 10: ...o add functionality These include Mode feature Function Offsets Allows the readout to track up to 5 reference positions at the same time Monitor Allows the readout to watch for unintended motion drift...

Страница 11: ...on then Pr1 3 Release the UNITS key 4 After a moment the value for Pr1 will display Change the parameter value using the PLUS or MINUS keys Default the parameter value using the DATUM key Advance to...

Страница 12: ...ue 0 000 Pr29 Upper limit value 5 000 inches Pr30 Offset additions to use 0 None Pr31 First offset value 0 5000 inches Pr32 Second offset value 2 0000 inches Pr33 Third offset value 3 0000 inches Pr34...

Страница 13: ...eds to be replaced immediately Check programming values after new battery is installed LOCK The keypad is LOCKed but an attempt was made to change the calibration Unlock keypad to fix see page 6 P LOC...

Страница 14: ...readout Switching power supply Part number 550 2003 001 Provides 15VDC power to the readout Wireless Data Transmitter Part number 700 1037 001 Transmits measurement values to a remote computer using Z...

Страница 15: ...stem ProKit 590 is available in measuring lengths up to 190 inches 4 8m SPC output comes standard Wireless data transmitter is available ProTable SA is a self contained single axis measuring table QC...

Страница 16: ...ProScale LCD Readouts version 4 Page 16 of 16 Thank you for choosing a ProScale Product IT WAS PROUDLY MADE IN THE USA Accurate Technology Inc 270 Rutledge Rd Unit E Fletcher NC 28732 USA 1 828 654 7...

Отзывы: