Manual Part # 800-1070-001, Rev G, 10-2008
Page 14 of 16
Programming Parameters
The Digi-Stop readout programming parameters are listed below.
Values in
[ ]
are the available range of values that can be entered for that
parameter. Factory defaults are shown in
Bold Red
.
Pr 1 – Datum Key
[
0
to + 999.999in
]
or
[
0
to +9999.99mm
]
The programmed value that will be recalled whenever the
DATUM
key is
pressed during normal operation.
Default = 0.00
Pr 2 – Reverse Readings
[
0
or 1
]
This parameter controls the direction of travel (positive vs. negative) when the
stop is moved.
Default = 0
Pr 3 – Key Lockout
[
0
or 1
]
This parameter controls the operation of the
+
,
-
and
DATUM
keys.
If enabled, (set to 1), these keys will not function and the
LOCK
LOCK
LOCK
LOCK
symbol will
appear on the display. This prevents accidental changes when pressing these
keys during normal operation.
Default = 0
Pr 4 – Readout Resolution
[
1,
2
, 3
]
This parameter sets the number of places to the right of the decimal point on
the readout.
A value of 1 –
Low
-
will display x.x.
A value of
2
– Normal -will display x.xx
A value of
3 –
High
-
will display x.xxx
Default = 2
NOTES:
Millimeters have a maximum of 2 places (even if parameter is set to 3.)
This setting has no effect when displaying fractions.