Manual Part # 800-1070-001, Rev G, 10-2008
Page 12 of 16
keys to provide a different offset. Moving the stop in either direction will
display the distance moved from the initial INC starting point (plus any offset).
To complete another incremental measurement from the new position,
momentarily press the
UNITS
key. The readout will again change to 0 (or the
previously programmed offset). To return to the ABS mode, press and hold
the
UNITS
key for approximately 3 seconds.
NOTES: when the readout is in incremental measuring mode the
UNITS
key no
longer functions to change the measurement units displayed.
The absolute position of the Digi-Stop is not lost when using the incremental
mode. When the readout is switched back to the absolute mode the readout
reflests the current stop position relative to your original calibrated absolute
setting.
Circuit board
Jumpers
The Digi-Stop readout has several user configurable jumpers consisting of
three pins and a ‘shorting block or jumper’.
The center of these three pins is ‘Common’. One end pin is labeled
A
and the
other end pin is labeled
B
.
JP1
FACTORY USE ONLY
JP2
Programming Lockout
Position
A
, Front Panel Programming is
ENABLED
Position
B
, Front Panel Programming is
DISABLED
JP1
JP2