Readout
Programming
Several functions of the Digi-Stop readout is user programmable. The
following describes what features and functions are available and how to
change the factory defaults to customize your Digi-Stop system..
To enter Programming Mode:
1. Press and hold the
UNITS
key then momentarily press the
DATUM
key.
2. The LCD will briefly display:
PG on
(Programming On), then
Pr 1
, (indicating Programming Parameter #1)
3. Release the
UNITS
key
4. The value stored in
Pr1
is displayed.
Once in the Programming Mode:
Moving up parameter list - Momentarily press the
UNITS
key to advance through
the Programming Parameter list, first displaying the Programming Parameter
number then the currently programmed value.
Moving down parameter list - Press and hold the
ON
/
OFF
key and momentarily
press the
UNITS
key to move backward through the Programming list.
Increase parameter value - Momentarily press the
PLUS
(+)
key while
displaying a Programming Parameter Value to increase the setting.
Decrease parameter value - Momentarily press the
MINUS
(-)
key while
displaying a Programming Parameter Value to decrease the setting.
Reset parameter value to default setting - Momentarily press the
DATUM
key
while displaying a Programming Parameter Value to reset the parameter to the
factory default value.
Exit programming mode - Press and hold the
UNITS
key. Momentarily depress
the
DATUM
key. The LCD will briefly display:
PG oFF
(Programming Off),
then return to normal operation.
NOTE
: The system will automatically exit
programming mode after 60 seconds of no key activity.
Momentarily
press
Press &
Hold