18
On flashing during
the interval count between defrosts;
the icon is steady on during the phase
defrost
Flashing on if the entrance
digital flow switch is active
(both with pump ON and with pump OFF)
On if at least one of the 2 water pumps
(evaporator pump or pump
capacitor) is on
On if the fans
are on
On if the relative compressor is
switched on; is flashing if the compressor
is in ignition timing
On if the exit
open collector is activ
On if the machine is on e
represents the operating status
Heat or Cool according to logic
set in parameter CF31
The HP icon and the LP icon are on
flashing in the event of a High alarm
o Low pressure active.
5.3 KEY FUNCTION
___________________________________________________
FUNCTION
KEY
Press and release in main view:
allows viewing
of the set point chiller (
SetC
label)
o heat pump (
SetH
label).
Press and release 2 times in main view:
if the energy saving function, dynamic
set point or for machines without
accumulation is enabled, the set icon is
on and the display shows the real working
set.
Press for 3 seconds and release
in main view:
allows modification of the set point
chiller / PdC.
Press and release in programming:
allows you to access the edit
of the selected parameter; allows
confirmation of the set value
in phase of parameter modification.
Press and release in the AlrM menu:
allows the reset of the alarm
(if resettable) from the ALrM menu.
Press and release:
from main view allows
the display of the probe values
configured (temperatures / pressures)
in the upper display and the corresponding
label in the lower display.
Press and release in programming:
allows you to scroll through folders
parameters (ST, CF, etc); allows it
scrolling the list of parameters.
Parameter being edited
increases its value.
Press and release:
from main view allows the display of the
probe values configured (temperatures /
pressures) in the upper display and the
label corresponding in the lower display
Press and release:
allows you to turn on the machine
(in chiller or heat pump)
or select std-by mode.
Press and release:
allows you to turn on the machine
(in chiller or heat pump)
or select std-by mode.
Press and release:
allows you to access the functions menu.
Press for 3 seconds and release: allows
you to adjust the clock in the models in
which it is provided. Press and release in
programming: allows to exit
from the parameter modification.
Simultaneous pressing of the keys
for 3 seconds:
allows access to programming
parameters.
Pressione contemporanea dei tasti
per 3 secondi:
1. consente l’uscita dalla
programmazione parametri.
2. la pressione contemporanea
prolungata dei tasti consente
l’ingresso in sbrinamento manuale.
As regards the use of the remote terminal (indications on the
display and meaning of the keys) refer to the previous paragraphs.
In the air / air units, if the remote terminal equipped with an NTC
probe (VICXS610) is used, by configuring
par. CF35 = 2 the display will show the ambient air temperature;
this probe will be used by the controller for thermoregulation. In
the event of a fault in the controller / remote terminal or an error
in the wiring, the lack of communication between the instrument
and the remote terminal will be signaled on the display with the
error message “noL” (no link).
5.4 ACCESS TO PARAMETERS
1 Press the SET and down arrow keys for a few seconds;
2 The icons
flash and the upper display
displays “ALL” (generic group of parameters);
3 Scroll through the parameter groups with the keys and select
the group containing the parameters to be modified; pressing the
button set allows you to access the list of parameters contained
Содержание HUB RADIATOR MINI 11.0
Страница 27: ...27 7 2 WIRING DIAGRAM HUB RADIATOR MINI XL 6 0...
Страница 28: ...28 7 3 WIRING DIAGRAM HUB RADIATOR MINI XL 8 0...
Страница 29: ...29 7 4 WIRING DIAGRAM HUB RADIATOR MINI XL 11 0...
Страница 30: ...30 7 5 WIRING DIAGRAM HUB RADIATOR MINI XL 16 0...
Страница 31: ...31 Marrone Nero Blu 7 6 WIRING DIAGRAM HUB RADIATOR MINI XL 24 0...
Страница 46: ...46...