![Accorroni HR 3.0 Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/accorroni/hr-3-0/hr-3-0_installation-manual_455731045.webp)
45
HR 3.0
5*m
3*m
15*m
5*m
20*g/m
HR 7.8
5*m
3*m
15*m
5*m
20*g/m
HR 9.0 INVERTER
5*m
3*m
15*m
5*m
20*g/m
Models
A
Maximum length allowed without adding refrigerant
B
Minimum allowed length of refrigerant gas
C
Maximum length of refrigerant gas piping
D
Maximum admissible height difference between O.U and I.U.
E
Additional refrigerant quantity over 5 meters
Table 1 - Permissible distances INDOOR UNIT - OUTDOOR UNIT
Failure to comply with this application will result in the
non-ignition by the authorized assistance
Attached A
Attached B
6 m
4 m
INDOOR
UNIT
OUTDOOR
UNIT
INSTALLATION
NOT CORRECT
Example B - Table1
Spiral length 1 meter
0,5 m
1,5 m
OUTDOOR
UNIT
INDOOR
UNIT
INSTALLATION
CORRECT
Example A - Table1
2 m
0,5 m
1,5 m
OUTDOOR
UNIT
INDOOR
UNIT
INSTALLATION
CORRECT
Example C - D - E - Table4
4 m
6 m
OUTDOOR
UNIT
INDOOR
UNIT
INSTALLATION
CORRECT
Distances of respect
side view
A
E
D
Distances of respect
view from above
C
A
B
LEGEND: (A = 15 cm) - (B = 50 cm) - (C = 15 cm) - (D = 60 cm) - (E = 100 cm)
Содержание HR 3.0
Страница 52: ...52 ...