The minimum permissible length of vertical coaxial pipes is 1 meter.
The maximum permissible length of vertical coaxial pipes 100/60 mm
is 7 meters. For each straight pipe added with a length of 1 meter, the
maximum length allowed must be decreased by 1 meter.
For each 90° bend added, the maximum length allowed must be
decreased by 1.5 meter.
For each 45° bend added, the maximum length allowed must be
decreased by 1 meter.
The roof drain decreases the maximum permissible length by 1.5
meters
4.6.2 CHIMNEY SWEEP FUNCTION
The boiler has a chimney sweep function which must be used for
measuring the combustion efficiency on site and for enter the
subsequent combustion regulation phase.
To activate the chimney sweep function it is necessary to keep the
keys pressed for the cycle time “
MODE
+
RESET
”.
If the keys are released before the end of the cycle time, the boiler
continues to operate normally.
If there is a sanitary request, the chimney sweep function is performed
on the sanitary, otherwise in heating.
Once you have entered the chimney sweep function, the letters “
Lo
”
appear in the display, alternating with the temperature value of the
heating water (eg. 45), indicating that the “chimney sweep function”
has been activated at minimum power.
The display shows the symbol “ ” if the burner is on. The boiler carries
out the ignition sequence and then goes on to operate at minimum
power (“
Lo
”).Press and hold the button for 3 seconds “ ”to switch to
the “chimney sweep function” at maximum power (“
Hi
”).
By keeping the button pressed for 3 seconds “ ” you go back to the
“chimney sweep function” at minimum power (“
Lo
”).
To exit the chimney sweep function, keep the key pressed for 3
seconds “
RESET
” and return to normal operation.
The duration of the chimney sweep function is 15 minutes.
4.6.3 CONNECTION TO THE GAS NETWORK
The gas supply pipe must have a section equal to or greater than that
used in the boiler.
The section of the pipeline depends on its length, the type of route and
the gas flow rate. It must therefore be dimensioned.
Observe the installation regulations in force which are
understood to be fully transcribed here.
Parametro
Valori impostabili Valori di default Note
P46
Selezione velocità modulante della pompa
0 - 1
1
0 = non modulata
1 = automatica 60% ÷ 100%
P47
Selezione ΔT per modulazione pompa (°C)
10 ÷ 40
20
P48
Selezione funzionamento pompa
0 - 1
0
0 = intermittente
1 = continuo
P49
Abilita OEM
0 ÷ 99
0
49 = consente la lettura / scrittura dei seguenti parametri
P50
Non usato
P51
Non usato
P52
Selezione riempimento automatico acqua
0 - 1
0
0 = non presente
1 = presente
NON MODIFICARE QUESTO VALORE
P53
Non usato
P54
Selezione flusso ACS minimo per attivazione
richiesta
10 ÷ 40 (lx10)/min
15 (1,5l/min)
P55
Selezione tempo postventilazione ACS
1 ÷ 30 sec x 10
3
P56
Selezione tempo postcircolazione ACS
0 ÷ 100 sec
30
P57
Selezione aumento dei giri del ventilatore
0 ÷ 10%
0
NON MODIFICARE
P58
Non usato
P59
Non usato
P60
Offset aggiuntivo alla temperatura di
spegnimento dopo accensione bruciatore
0 ÷ 20
0
NON MODIFICARE
P61
Selezione allarme temperatura scarico fumi
20 ÷ 150
105
P62
Non usato
P63
Non usato
P64
Non usato
P65
Selezione durata Antilegionella
5 ÷ 30 min
15 min
Solo per bollitore con termostato
P66
Non usato
P67
Non usato
P68
NON MODIFICARE -
Non usato
P69
NON MODIFICARE -
Non usato
P80
Selezione ΔT riscaldamento per rilevazione
blocco circolazione
0 ÷ 20
5
0 = disabilitato
P81
Temperatura massima riscaldamento
0 ÷ 150
90
0 = disabilitato
P82
Selezione ΔT mandata/ritorno massimo
accettabile
0 ÷ 50
30
0 = disabilitato -
NON MODIFICARE
P83
Selezione mesi mancanti alla manutenzione
0 ÷ 255
0
0 = disabilitato
P98
Reset TSP ai valori di fabbrica
0 - 1
0
P99
Reset OEM ai valori di fabbrica
0 - 1
0
Tabella 10 - Tabella generale parametri TSP
4.6.4 TSP PARAMETERS THAT CAN BE SET FROM INTERFACE AND REMOTE CONTROL
Содержание HR 3.0
Страница 52: ...52 ...