41
IE1-1230-B
February 2001
If a Walk Through zone is activated first when the system is Full Set it causes a full
alarm.
5 24 Hour Tamper
A 24 Hour Tamper zone is used for system tampers and for zones covering sensitive areas
such as stock rooms, fire doors, external bell box, etc.
If a 24 Hour Tamper zone is activated when the system is Unset, the keypads sound and
the corresponding zone LED (No.) on the keypad illuminates. External sounders do
not
operate.
It is strongly recommended that a zone programmed as 24 Hour Tamper is programmed
in one of the following ways:
Programmed as 24 Hour Tamper in Groups 1 (Full Set), 2 (Part Set) and 3 (Night
Set).
Programmed as 24 Hour Tamper in Group 1 (Full Set), and, 0 (Not Used) or 24
Hour Tamper in Groups 2 (Part Set) and 3 (Night Set).
Programming a zone in Group 1 (Full Set) also covers the unset condition.
6 PA Silent
The PA Silent zone type is assigned to a panic button. Activation of a PA Silent zone does
not cause any audible indication and no indication is given on the keypad display until a
valid code is entered at the keypad. The activation is reported via the Accord xpC dialler.
It is strongly recommended that a zone programmed as PA Silent is programmed in one
of the following ways:
Programmed as PA Silent in Group 1 (Full Set), 2 (Part Set) and 3 (Night Set).
Programmed as PA Silent in Group 1 (Full Set), and, 0 (Not Used) or PA Silent in
Groups 2 (Part Set) and 3 (Night Set).
Programming a zone in Group 1 (Full Set) also covers the unset condition.
7 PA Audible
A PA Audible zone is assigned to a panic button. Activation of a PA Audible zone initiates
a full alarm condition. The activation is also reported via the Accord 8C-R downloader.
It is strongly recommended that a zone programmed as PA Audible is programmed in one
of the following ways:
Programmed as PA Audible in Groups 1 (Full Set), 2 (Part Set) and 3 (Night Set).
Programmed as PA Audible in Group 1 (Full Set), and, 0 (Not Used) or PA
Audible in Groups 2 (Part Set) and 3 (Night Set).
Programming a zone in Group 1 (Full Set) also covers the unset condition.