Accord XPC Скачать руководство пользователя страница 2

ii

Содержание XPC

Страница 1: ...i Installation Manual...

Страница 2: ...ii...

Страница 3: ...ncillaries Pack 7 Initial Mounting 7 Removing and Replacing the Accord xpC PCB 8 Fitting the Tamper Switch 9 Connecting Keypads Sounders and a Speaker to the Accord xpC 10 Mounting and Wiring the LED...

Страница 4: ...r Fails 23 System Programming Group 5 System Options 23 Group 5 Option 1 Audible Warning of AC Loss 24 Group 5 Option 2 Supplementary Entry 24 Group 5 Option 3 System Reset for Alarm 24 Group 5 Option...

Страница 5: ...Group 9 Parameters 35 Group 9 Option 1 Communicate Omitted Zones 36 Group 9 Option 2 Invert Set Unset Signals 36 Group 9 Option 3 Double Knock Zone 36 Group 9 Option 5 Restore Signals on Unset or Rese...

Страница 6: ...g the Time and Date 47 Hot Keys 48 Section 5 Systems Indications and What they Mean 49 Section 6 Handing the System Over to the User 51 Fill In the User Instructions 51 Appendix A Specifications 51 Pa...

Страница 7: ...ion ample light and easy access for servicing and maintenance It is not suitable for siting externally or in harsh environments where it could be subject to high humidity extremes of temperature chemi...

Страница 8: ...A fuses must be fitted to both circuits Where a flexible cable is connected to the control having cores coloured brown and blue it is important to connect the wires to the mains terminal block as foll...

Страница 9: ...erminals Note Prevent exposure to potentially lethal voltages from the PSTN by replacing the Control Panel cover when connection to the BT master socket is complete Inter connection circuit equipment...

Страница 10: ...gium Greece Liechtenstein Portugal United Kingdom Denmark Iceland Luxembourg Spain Germany Finland Ireland The Netherlands Sweden Note Contact the equipment supplier before using the Accord xpC on any...

Страница 11: ...s fuse with the same type and rating that is Rating 200 mA anti surge T Construction Glass cartridge Dimensions 20 mm length 5 mm diameter Conformance BS EN 60127 2 and IEC127 2 There are three on boa...

Страница 12: ...6...

Страница 13: ...rtion of the keyhole All cables should be brought into the enclosure base via the cable entry points shown in figure 2 1 There are six cable entry holes for the entry of alarm cables There is one a c...

Страница 14: ...nd place the PCB on top of the PCB support pillars 4 Release the PCB mounting clips ensuring that they spring back into place and that the PCB is held firmly in place For information on the layout of...

Страница 15: ...of the Knockout Tamper Posts see figure 2 1 The installer should knockout one of these Tamper Posts from the enclosure base and ensure the spring is securely attached to the short end of the Tamper P...

Страница 16: ...lp dislodge knockouts 4 Securely mount the back case to a wall or electrical box via the mounting holes Ensure The Tamper Tab is securely screwed down 3 The remote keypad PCB should be wired to the co...

Страница 17: ...r Double Balanced Zones Figure 2 7 Zone Wiring for US EOL Zones Zone Links The eight zones the zone tamper and the bell tamper circuits can be shorted using the Zone Links provided in the ancillaries...

Страница 18: ...s failure by the addition of a Stand by battery with a maximum rating of 7 2 Ahr Calculate the system quiescent current draw and multiply this by the number of hours required for stand by cover for ex...

Страница 19: ...possible to simultaneously connect a number of items to one line of the PSTN The limit is determined by summing the Ringer Equivalence Number REN shown on each item of apparatus ensuring that the sum...

Страница 20: ...Xs When connected to a PBX the Accord xpC can be programmed to pause for two seconds between the dialling of the digits Final Mounting Once all cable entries have been made to the enclosure and connec...

Страница 21: ...uxiliary voltage is under 13 5 V too much current is being drawn For the current consumption of the control panel and keypads see Appendix A Note If the auxiliary voltage is between 13 5 V and 14 V d...

Страница 22: ...16...

Страница 23: ...will abort the communication Note Pressing the and keys together within five seconds of power up defaults the master code and the engineer code to factory settings Pressing the and keys together withi...

Страница 24: ...number as a sequence of digits Programming Groups 1 2 and 3 Zone Programming For Full Part and Night Set Programming Groups one to three are used to programme the eight zones for each of the three set...

Страница 25: ...for Part Set The second digit is the zone number 1 8 The third digit is the zone type Example In Programming Mode press 2 2 3 This programmes zone 2 as an Alarm in the Part Set mode and is accompanie...

Страница 26: ...he option value Table 3 4 Night Set Zones Table 3 5 Group 4 System Options Note The default programming is shown in brackets in Table 3 4 t e S t h g i N p u o r G e n o Z o N e n o Z t l u a f e D e...

Страница 27: ...ows the Part Set exit timer to be silent audible through the keypad or audible through the keypad and internal sounder Night Set will always have a silent exit timer but this option will affect the Ni...

Страница 28: ...The 0 V supply is removed for five seconds when the setting procedure is initiated to ensure devices are reset before the system sets After an alarm activation the 0 V will be re moved when the system...

Страница 29: ...e R g e N 1 d e i l p p A g e N 0 t u p t u O r e g g i r T 7 0 5 s r e p m a T y a D r o f t e s e R r e e n i g n E 8 e r o t s i n h c e T r o r e e n i g n E 3 e r o t s i n h c e T 2 r e e n i g...

Страница 30: ...d Group 5 Option 3 System Reset for Alarm This option determines how the system may be reset after an alarm condition 0 Customer 1 Engineer 2 Technistore 3 Engineer or Technistore Set to 0 Customer Us...

Страница 31: ...ancelled by operating a zone programmed as Keyswitch This option defaults to 0 disabled Group 5 Option 6 Bell Output When set to 0 the Bell output is negative applied positive removed When set to 1 th...

Страница 32: ...ption defaults to 0 customer Note This option only affects Tamper conditions occurring when the system is unset It does not affect tamper conditions occurring when the system is in one of the set mode...

Страница 33: ...umber Multiple entries may be used for example three consecutive presses would give a six second pause If less than 20 digits are used end programming by pressing To delete a telephone number press th...

Страница 34: ...Downloader software is subject to menu option Group 7 Option 8 Downloader Options Group 6 Option 5 Downloader Telephone Number A Downloader Telephone Number of up to 20 digits may be entered If less t...

Страница 35: ...zones report using Code 1 in Channel 2 and restore using Code 3 in Channel 2 Alarm zones report using Code 1 in Channel 3 and restore using Code 3 in Channel 3 Open Unset zones report using Code 2 in...

Страница 36: ...efaults to 0 UK System Programming Group 7 Comms Options 2 Group 7 Option 1 Dual Reporting This option can be programmed in one of two modes 0 Single Report 1 Dual Report This option defaults to 0 Sin...

Страница 37: ...Dial also known as Tone Note Although this equipment can use either Pulse or DTMF dialling only the performance of the DTMF signalling is subject to regulatory requirements for correct operation It i...

Страница 38: ...ontact is programmed Group 4 Option 1 0 Group 7 Option 7 Line Fail If this option is disabled set to 0 there is no internal alarm or indication in the event of a line fail condition being detected If...

Страница 39: ...rm all system operations No Unsetting 2 permits access the system to perform a download at any time However the Downloader cannot unset the system from a set condition Group 7 Option 9 Zone Auto Omit...

Страница 40: ...truder Comm enabled Group 8 Option 4 Communicate Set Unset This option has two settings 0 No Set Unset Comm disabled 1 Yes Set Unset Comm enabled This option defaults to 0 Set Unset Comm disabled Grou...

Страница 41: ...day test period 3 Periodic Test Report Comm enabled 31 day test period When enabled set to 1 2 or 3 the time between periodic test signals is dependant on the option selected This option defaults to 0...

Страница 42: ...n Channel 4 Group 9 Option 3 Double Knock Zone This option allows one zone to be programmed as a Double Knock zone The control panel will only acknowledge the Double Knock zone if it is activated twic...

Страница 43: ...d time window when deviation occurs During the 30 seconds an internal alarm warning should sound External bells communications triggers will be withheld until 30 seconds has passed or the entry period...

Страница 44: ...This option is for use with Technistore reset The engineer can programme the Technistore Version Number with a valid range of 000 to 255 To programme the Technistore Version Number Enter Programming M...

Страница 45: ...ARC 2 Overide report PA channel to ARC 3 Overide report Alarm channel to ARC 4 Overide report Set Unset channel to ARC 5 Overide report Day Tamper channel to ARC 6 Overide report RF Low Battery channe...

Страница 46: ...when the system is Part Set or Night Set then 2 Keyswitch A Keyswitch zone has a latching operation The Keyswitch should be wired across the zone terminals to Full Set the system Opening the Keyswitch...

Страница 47: ...a PA Silent zone does not cause any audible indication and no indication is given on the keypad display until a valid code is entered at the keypad The activation is reported via the Accord xpC diall...

Страница 48: ...o Set zones have no effect when the system is set 9 Fire A Fire zone is used for fire detection devices with normally closed outputs It is strongly recommended that a zone programmed as Fire is progra...

Страница 49: ...sy Set is programmed you may set the system by pressing the key then the 1 Full Set key See SECTION 3 Programming the Accord Group 4 Option 8 Easy Set Part Set 2 To Part Set the system Enter your User...

Страница 50: ...r code Unsetting After or During an Alarm On the keypad the LED or zone number corresponding to the first zone to go into alarm illuminates Entering a User Code stops any alarm that is in progress To...

Страница 51: ...r a valid user code press the 6 key and then press the key When the zones are omitted set the system in the normal way All zones will be restored to normal non omitted operation when the system is nex...

Страница 52: ...the system To remove their own User Code enter code select the codes option by pressing 8 press the appropriate key for your user number and press the key Example To delete User Code 2 from the system...

Страница 53: ...f the Log display The key can be used to terminate event log veiwing at any time Viewing the Event Log from Ademco Microtech Downloader Software The Ademco Microtech Downloader software allows the 250...

Страница 54: ...s enabled Group 5 Option 4 Assistance Fire and Panic alarms will function via a double push on the keypad see table below Note Hotkey buttons must be pressed for 2 seconds for hotkey function software...

Страница 55: ...d i l o s D E L E N O Z T L U A F E N I L d i l o s d i l o s D E L E N O H P E L E T L I A F S M M O C g n i h s a l f g n i h s a l f D E L E N O H P E L E T T U O K C O L d i l o s g n i h s a l f...

Страница 56: ...50...

Страница 57: ...y the operation of the system to the user Appendix A Specifications Panel Specification Physical Width 195 mm Height 285 mm Depth 90 mm Electrical Mains Input 230 V a c 10 50 Hz Back up Battery Up to...

Страница 58: ...nter to the System Installing a Printer Two printer leads are required to connect the Accord xpC panel to a serial printer 1 Master Printer Lead part no 2011 095 connects from the printer to the Adapt...

Страница 59: ...a r e u q e C a r e u q e C a m g i S y t i r u c e S R Q C s l a n i m r e T d r o c c A L L E B L L E B L L E B P M A T L L E B R P M A T B R T S s l a n i m r e T x o B l l e B F F O D L O H E V N...

Страница 60: ...Y OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HERE OF IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR B...

Страница 61: ...55 IE1 1230 B February 2001...

Страница 62: ...56 IE1 1230 B...

Отзывы: