Zone Type Definitions
General Information
The Accord xpC has ten zone types, these are:
0 Not Used
Zones which are unused should be programmed as 0 Not Used. These zones should also
be linked out using the appropriate zone link or 1K resistor provided in the Auxilliary
pack.
1 Final Exit
The Final Exit zone is used for the entry/exit route(s), usually assigned to the front door
or other main entry point(s). The zone becomes operational when the system is set or
setting.
The Exit Time must be set to infinite (410) for a Final Exit zone to terminate a Full
Setting procedure.
Activation of a Final Exit zone while the system is set, initiates the unsetting procedure.
The keypads beep and all Intermediate Exit Zones are isolated. A valid User Code must
be entered at the keypad or a Keyswitch Zone activated before the Entry Time has elapsed.
The Exit Time is fixed at 30 seconds when the system is Part Set or Night Set then.
2 Keyswitch
A Keyswitch zone has a latching operation.
The Keyswitch should be wired across the zone terminals to Full Set the system. Opening
the Keyswitch zone will start the Full setting procedure. Closing the Keyswitch zone
(closed circuit) instantly unsets the system.
The Keyswitch can also unset the system from Part or Night Set when programmed in
group 2 and 3.
It is strongly recommended that the Keyswitch should be fitted in a Tamper protected
case with the Tamper switch connected in series with the other Tamper circuits at the
control panel.
3 Intruder
An Intruder zone is used on devices that require an instant alarm if activated when the
system is Set. During the Set state, zone activations cause internal sounders and external
sounders to activate.
4 Walk Through
A walk Through zone is used with the Final Exit zone. The unsetting procedure is initiated,
all Walk Through zones are omitted during the Entry Time when the system is set and a
Final Exit zone is activated. This gives users access to a keypad or keyswitch.