background image

 

6

 

 

The B symbol indicates this product 
has a degree of protection against 
electric shock for type B equipment. 

 

Caution, read the instructions 
before use. 

IPX4

 

Degree of protection against liquid 
ingress. 

 

Do not dispose of in household 
waste. 

 

Degree of protection against 
electric shock: Class II Double 
Insulated. 

 

For indoor use only 

For or a full list and explanation of symbols used see 
Section 23. 
 

7.

 

Assembly 

 

 

1.

 

Check that the delivery is complete and whether 
any visible damage has occurred to the chair 
during transport. 

2.

 

Remove the cardboard box and other packaging 
and the chair should appear as fig 1.

 

 

3.

 

The following components should be present: 

A.

 

Chair frame assembly 

B.

 

Right Sidepiece 

C.

 

Left Sidepiece 

D.

 

3 x Backrest cushions 

E.

 

Footplate 

F.

 

Instruction manual 

4.

 

Remove the R-clip (Fig 2, Item 1), then remove the 
clevis pin (Fig 2, Item 2).

 

5.

 

Rotate the backrest upward and hold in place.  
Align the mounting hole at the bottom of the gas 
strut (Fig 3, Item 2) and the mounting hole at the 
bottom of the backrest lockout slide (Fig 3, Item 3) 

with the clevis at the back of the main frame (Fig 
3, Item 1). Ensure the Tilt-in Space operating cable 
(Fig 3, Item 4) is routed between the backrest and 
the backrest actuator assembly.

 

 

 

 

 

 

 

6.

 

Insert the clevis pin (Fig 4, Item 1) through the clevis 
at the back of the main frame, the gas strut and 
the backrest lockout slide.  Secure the pin with the 
R-clip (Fig 4, Item 2).  

 

WARNING 

 
Assembly MUST be carried out by suitably 
trained and qualified personnel. 
All functions MUST be tested and approved 
after assembly by suitably trained and 
qualified personnel. 
Assembly MUST take place in a clear, 
uncluttered area and children and pets 
should be kept away. 
Only the power supply supplied with the chair 
may be used. 
If chair has become soiled or contaminated 
during transit refer to cleaning and 
disinfection instructions. 

Figure 1 - Chair as delivered (side pieces are loose) 

Figure 2 

 Backrest clevis pin 

1

 

Figure 3 

Содержание Configura Advance Chair

Страница 1: ...Configura Advance Chair Instruction Manual IFU SC1 001EN Rev 04 May 2022...

Страница 2: ...ified as a Class 1 Medical Device in accordance with the Medical Devices Regulation 2002 as amended and the Medical Device Regulation 2017 745 Notice to User If a serious incident occurs in relation t...

Страница 3: ...ents may be used otherwise Accora cannot guarantee against any damage that might occur 14 Inappropriate routing of accessory cables e g cushion pump cable could lead to dangerous electrical hazards if...

Страница 4: ...ng homes or convalescent units The Configura Advance chair may also be placed in private homes where there is unlikely to be 24 hour supervision by clinical staff but where the patient or caregiver is...

Страница 5: ...specification Mains electrical system Description Value Supply voltage 100 240VAC Supply frequency 50 60Hz Max supply current 3 9 Amps Degree of protection against liquid ingress IPX4 Degree of protec...

Страница 6: ...and hold in place Align the mounting hole at the bottom of the gas strut Fig 3 Item 2 and the mounting hole at the bottom of the backrest lockout slide Fig 3 Item 3 with the clevis at the back of the...

Страница 7: ...e other side 10 Secure the backrest cushions to the backrest with the Velcro flaps Each cushion is attached to the backrest with the Velcro flap at the top of the cushion The top cushion has a double...

Страница 8: ...djusted from 330mm 13 to 533mm 21 The height is adjusted using two plungers Chair Width adjustment 1 Make sure a patient is not in the chair 2 Make sure the brakes on all 3 locking castors are locked...

Страница 9: ...ir 2 Undo the hand screw and sidepiece locking plunger Figure 8 3 Pull the sidepiece from the chair seat frame undo the screws Figure 15 from the fixing bars Figure 15 4 Locate the fixing bars to the...

Страница 10: ...that the plungers that secure the footplate Fig 18 Items 1 2 are in the closed position Fig 19 2 Take the footplate Fig 21 and insert the two tapered spigots Fig 21 Items 1 2 into the two sockets eith...

Страница 11: ...is used to adjust this angle 3 Manual Forward Tilt The chair can tilt forwards from 7 degrees normal tilt to 10 degrees of forward tilt with lock bolts removal 4 Manual Leg rest The leg rest can be ad...

Страница 12: ...e 3 Release the lever to lock the tilt in space angle Manual Forward Tilt Adjustment This function enables some patients to exit the chair more easily however it must only be used following a risk ass...

Страница 13: ...est lockout slide Fig 29 Item 1 3 Release the backrest lockout slide by lifting the locking lever away from the backrest lockout slide The backrest can now be adjusted using the backrest lever 4 Pull...

Страница 14: ...f the patient 1 Remove the footplate See section 9 2 Make sure the brakes on all 3 locking castors are locked on 3 Ensure it is safe to move the chair into the forward tilt position 4 Press buttons 4...

Страница 15: ...the charging lead is stretched the two sections may come apart from each other Move the chair nearer to the mains socket and reconnect the two sections of the charging lead We recommend that the batte...

Страница 16: ...he lever will flip up 3 Push the chair forward moving slightly from side to side to ensure 4 To unlock the castor swivel press on the top of the green lever to bring it back horizontal Directional loc...

Страница 17: ...o not use detergents that could alter the structure or behaviour of the plastics petrol etc Clean by wiping with a damp cloth Alternatively use Microfibre cleaning cloth without any soap For extreme s...

Страница 18: ...user or another person The following checks must be carried out 1 Does the chair operate as per its intended purpose without unexpected noise or motion 2 Are there any signs of abuse or excessive wear...

Страница 19: ...SPR 11 Group 1 The chair uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions...

Страница 20: ...s to earth 1kV differential mode Not applicable Mains power quality should be that of a typical commercial or hospital environment Voltage Dips short interruptions and voltage variations on power sup...

Страница 21: ...nsmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range Interference may occur in the vicinity of equipment marked with the followi...

Страница 22: ...ance according to frequency of transmitter M 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 1...

Страница 23: ...inst liquid ingress Do not dispose of in household waste Degree of protection against electric shock Class II Double Insulated For indoor use only Medical Device in accordance with EU Medical Device R...

Страница 24: ...24 IFU SC1 001EN REV 04 Accora Barrington Road Orwell Cambridge SG8 5QP United Kingdom T 44 0 1223 206100 info accora care www accora care...

Отзывы: