Configura Advance Chair position setting ranges:  

 

 

 

 

Key parts of the chair: 

 

5.

 

Accessories 

 

Part number 

Description 

BRPOSKT-0-SC1-030 

Postural backrest includes all 
metal frames and cushions 

HRPF-0-SC1-020 

Backrest profiled headrest 

DRPSIDKT-0-SC1-030 

Dropdown sidepieces and 
covers, set of 2 

DRPARM-0-SC1-230 

Dropdown armrests, 400-550mm 
(16-

22”)

, set of 2 

DRPARM-0-SC1-030 

Dropdown armrests, 350-500mm 
(14-

20”)

, set of 2 

DRPARM-0-SC1-130 

Dropdown armrests, 450-550mm 
(18-

22”)

, narrow, set of 2 

EXTLAT-0-SC1-020 

External laterals, set of 2 

TRAY-0-SC1-000 

Tray 

PELVS4-0-SC1-000 

Pelvic positioning belt 

KITCA-0-SC1-000 

Advance Cushionair system 

For more information, refer to the relevant instruction 
manual or contact Accora. 

6.

 

Electrical specification 

Mains electrical system: 

Description 

Value 

Supply voltage 

100 

 240VAC 

Supply frequency 

50/60Hz 

Max supply current 

3.9 Amps 

Degree of protection 

against liquid ingress 

IPX4 

Degree of protection 
against electric shock 

Class II Double Insulated 

Low voltage electrical system: 

Description

 

Value

 

Operating voltage 

24V 

Battery Specifications 

-

 

Type 

Lithium Ion 

-

 

Output Voltage 

25.9V 

-

 

Capacity 

2.25Ah 

-

 

Duty Cycle 

5% (1 min continuous, 19 min off) 

-

 

Charging time 

Approx. 10 hours 

-

 

LED light 

Solid yellow 

 charging, No light 

 

fully charged, Flashing yellow 

 

error during charge 

-

 

Recharging 

during storage 

First recharge of the battery must 
be no later than 12 months after 
production date stated on the 

label.  Thereafter the battery 
must be recharged at least every 
12 months. 

 

 

Standard position range settings 

Forward tilt position setting

 

1

 

2

 

3

 

4a

 

5

 

4b

 

Seat 

Leg Rest 

Foot Plate 

Right Sidepiece 

Left Sidepiece  

Backrest 

1

 

5

 

2

 

3

 

4b

 

4a

 

Содержание Configura Advance Chair

Страница 1: ...Configura Advance Chair Instruction Manual IFU SC1 001EN Rev 04 May 2022...

Страница 2: ...ified as a Class 1 Medical Device in accordance with the Medical Devices Regulation 2002 as amended and the Medical Device Regulation 2017 745 Notice to User If a serious incident occurs in relation t...

Страница 3: ...ents may be used otherwise Accora cannot guarantee against any damage that might occur 14 Inappropriate routing of accessory cables e g cushion pump cable could lead to dangerous electrical hazards if...

Страница 4: ...ng homes or convalescent units The Configura Advance chair may also be placed in private homes where there is unlikely to be 24 hour supervision by clinical staff but where the patient or caregiver is...

Страница 5: ...specification Mains electrical system Description Value Supply voltage 100 240VAC Supply frequency 50 60Hz Max supply current 3 9 Amps Degree of protection against liquid ingress IPX4 Degree of protec...

Страница 6: ...and hold in place Align the mounting hole at the bottom of the gas strut Fig 3 Item 2 and the mounting hole at the bottom of the backrest lockout slide Fig 3 Item 3 with the clevis at the back of the...

Страница 7: ...e other side 10 Secure the backrest cushions to the backrest with the Velcro flaps Each cushion is attached to the backrest with the Velcro flap at the top of the cushion The top cushion has a double...

Страница 8: ...djusted from 330mm 13 to 533mm 21 The height is adjusted using two plungers Chair Width adjustment 1 Make sure a patient is not in the chair 2 Make sure the brakes on all 3 locking castors are locked...

Страница 9: ...ir 2 Undo the hand screw and sidepiece locking plunger Figure 8 3 Pull the sidepiece from the chair seat frame undo the screws Figure 15 from the fixing bars Figure 15 4 Locate the fixing bars to the...

Страница 10: ...that the plungers that secure the footplate Fig 18 Items 1 2 are in the closed position Fig 19 2 Take the footplate Fig 21 and insert the two tapered spigots Fig 21 Items 1 2 into the two sockets eith...

Страница 11: ...is used to adjust this angle 3 Manual Forward Tilt The chair can tilt forwards from 7 degrees normal tilt to 10 degrees of forward tilt with lock bolts removal 4 Manual Leg rest The leg rest can be ad...

Страница 12: ...e 3 Release the lever to lock the tilt in space angle Manual Forward Tilt Adjustment This function enables some patients to exit the chair more easily however it must only be used following a risk ass...

Страница 13: ...est lockout slide Fig 29 Item 1 3 Release the backrest lockout slide by lifting the locking lever away from the backrest lockout slide The backrest can now be adjusted using the backrest lever 4 Pull...

Страница 14: ...f the patient 1 Remove the footplate See section 9 2 Make sure the brakes on all 3 locking castors are locked on 3 Ensure it is safe to move the chair into the forward tilt position 4 Press buttons 4...

Страница 15: ...the charging lead is stretched the two sections may come apart from each other Move the chair nearer to the mains socket and reconnect the two sections of the charging lead We recommend that the batte...

Страница 16: ...he lever will flip up 3 Push the chair forward moving slightly from side to side to ensure 4 To unlock the castor swivel press on the top of the green lever to bring it back horizontal Directional loc...

Страница 17: ...o not use detergents that could alter the structure or behaviour of the plastics petrol etc Clean by wiping with a damp cloth Alternatively use Microfibre cleaning cloth without any soap For extreme s...

Страница 18: ...user or another person The following checks must be carried out 1 Does the chair operate as per its intended purpose without unexpected noise or motion 2 Are there any signs of abuse or excessive wear...

Страница 19: ...SPR 11 Group 1 The chair uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions...

Страница 20: ...s to earth 1kV differential mode Not applicable Mains power quality should be that of a typical commercial or hospital environment Voltage Dips short interruptions and voltage variations on power sup...

Страница 21: ...nsmitters as determined by an electromagnetic site survey a should be less than the compliance level in each frequency range Interference may occur in the vicinity of equipment marked with the followi...

Страница 22: ...ance according to frequency of transmitter M 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 1...

Страница 23: ...inst liquid ingress Do not dispose of in household waste Degree of protection against electric shock Class II Double Insulated For indoor use only Medical Device in accordance with EU Medical Device R...

Страница 24: ...24 IFU SC1 001EN REV 04 Accora Barrington Road Orwell Cambridge SG8 5QP United Kingdom T 44 0 1223 206100 info accora care www accora care...

Отзывы: