46 / 58
Reference: MI211062
komplet 211062
Version: 00
46 / 58
11.2.1-Replacing the wire ropes
Only wire ropes recommended and supplied by ACCESUS guarantees the start up of the hoists
safely
The wire rope has a nominal pipe size of 8,3mm, a hook with a safety clip in one end and a rounded
tip at the other side. The wire rope has a nameplate which identifies the origin, diameter and length.
The wire rope must be replaced in this cases:
a) Reduction of the diameter. Minimum diam-
eter 7,4 mm (for a wire rope with a nominal pipe size
of 8,3 mm).
b) Breaking of more than 10 threads over a
length of 25 cm for a wire rope of Ø8,3 mm.
c) Deformity or breaking of his clamps.
d) Wire rope crushed or stripped.
e) Hard oxidation.
11.1-Wire ropes
Only the wire ropes recommended and supplied by ACCESUS guarantee the operation of the lifts
Cleaning: If necessary, brush dry, dirty wire ropes and, if necessary, grease them again.
NEVER CLEAN WIRE ROPES WITH HIGH PRESSURE WATER!
Greased: Lifting wire ropes should be greased regularly. To do this use IGOL SHP 50 grease or
equivalent and distribute it by means of a cloth along the length of the wire rope.
NEVER LUBRICATE THE CABLE WITH LUBRICANTS CONTAINING BISULPHITES! (eg Molycote).
No maintenance is required on the engine, gear or brake until it reaches the annual review inter-
val.
-In case of dirt, clean from the outside.
-Keep brake free of oil and grease.
11.2-Elevator