25 / 58
Reference: MI211062
komplet 211062
Version: 00
25 / 58
DANGER!
Danger of death due to fall of ob-
jects, fall from different level and
/ or breaks.
Danger of death due to fall of objects, fall from different level and
/ or breaks.
-Do not stay under suspended loads.
-If necessary, block the danger zone.
When performing the following tests, the equipment must be loaded with the maximum load limit,
in order to be able to check the operation of the safety devices.
6.6.2- Running test for electric elevator e.lift501
6.6.2.1- Check the operation of the electric elevation system
Check the service brake
- Connect the lift upwards until the wire rope is tightened.
- Raise the load approximately 1m
- Stop the movement.
- Move it down.
- Stop de movement.
The stopping distance must not exceed 10cm. The elevator must hold the load.
- Download the load and loosen the wire rope.
- Stop the elevator.
The elevator must hold the wire rope.
If the lift does not hold the load, the wire rope and / or the stopping distance is greater than 10cm,
have the elevator checked and repaired by ACCESUS or an authorized workshop by ACCESUS.
Check the operation of the detectors
A
- Check the UPPER limit switch, see section 7.6.
-Shoot the limit switch manually.
-The upward movement must be stopped, the winch must hold the load and the descent must be
possible.
B
- Check the phase control relay, see section 7.7
If the phase control relay does not disconnect the drive when it is fi rst connected and the drive is
moved in the correct direction with the UP button, everything is correct. If the direction is not correct or the
phase control relay disconnects the drive, use the phase inverter, see 7.7.
Check operation emergency stop
-Connect the lift upwards until the wire rope is tightened.
- Press EMERGENCY STOP
The power supply to the motor must be switched off immediately. The elevator must hold the wire
rope.