Installation Manual – RPSP
INS-RPSP-EN-05
If the operation has been performed correctly, the
D14 LED will light up on the board.
Fig. 48 – Switching ON of D14.
Take the remote control (TX module) to the
maximum distance desired and push any of the
commands, ascend or descend (the D14 led will
switch off).
Fig. 49 – Press any command to calibrate the maximum operating distance.
When the procedure is complete put the dip
switches back in their original position on the
receiver (the position must be the same as the
transmitters, in the absence of other nearby
systems the standard configuration is with both
in the OFF position).
The set distance will be indicative as the radio
system changes its behaviour when the
environmental conditions change.
OFF
Fig. 50 – standard configuration
4.4.3
Onboard Alarm
This is situated inside of the body of the machine and
has been pre-installed in the factory by connector E
Fig. 51 – Onboard Alarm Connector
LED D14
Содержание RPSP
Страница 1: ...Supra Linea Inclined Platform Lift Installation Manual INS RPSP EN 05 ...
Страница 6: ...5 Installation Manual RPSP INS RPSP EN 05 Fig 2 General exploded view ...
Страница 7: ...6 Installation Manual RPSP INS RPSP EN 05 Fig 3 Register exploded view ...
Страница 8: ...7 Installation Manual RPSP INS RPSP EN 05 Fig 4 View of the guide ...
Страница 9: ...8 Installation Manual RPSP INS RPSP EN 05 Fig 5 Machine body ...
Страница 11: ...10 Installation Manual RPSP INS RPSP EN 05 Fig 7 Platform Fig 8 Lateral Motorized Flap SML ...
Страница 12: ...11 Installation Manual RPSP INS RPSP EN 05 Fig 9 Frame crush proofing Fig 10 Anti impact ...
Страница 14: ...13 Installation Manual RPSP INS RPSP EN 05 Fig 12 Three phase electrical motor connections ...
Страница 57: ...56 Installation Manual RPSP INS RPSP EN 05 ...
Страница 58: ...57 Installation Manual RPSP INS RPSP EN 05 ...
Страница 60: ......