18
Installation Manual – RPSP
INS-RPSP-EN-05
Remove the guide from the packaging
and place it near the stairs. Do not
destroy the packaging – it could be useful
for preventing scratches during the
operation.
Position the rail, using the figures
corresponding to the high rise and
inclination in the diagram, and making
use of the pre-drilled holes on the guide
and the adjustable stanchions provided.
As an option the clamps for fixing the rail
to the stanchions can be used (see Fig.
15).
Fig. 15 – Positioning, adjustment and fixing the stanchion at the end of the guide
Position the rail toward the middle of the
stair (i.e. not against the wall) – this will
make it easier to mark the position of the
holes (see Fig. 16)
Lay out the remaining stanchions in the
position shown in the diagram, just
resting them on the step tread. The
anchoring pitch must not be greater than
750 mm and in any case always refer to
the instructions in the specific assembly
diagram.
Fig. 16– Positioning of the guide mid-stairs
Содержание RPSP
Страница 1: ...Supra Linea Inclined Platform Lift Installation Manual INS RPSP EN 05 ...
Страница 6: ...5 Installation Manual RPSP INS RPSP EN 05 Fig 2 General exploded view ...
Страница 7: ...6 Installation Manual RPSP INS RPSP EN 05 Fig 3 Register exploded view ...
Страница 8: ...7 Installation Manual RPSP INS RPSP EN 05 Fig 4 View of the guide ...
Страница 9: ...8 Installation Manual RPSP INS RPSP EN 05 Fig 5 Machine body ...
Страница 11: ...10 Installation Manual RPSP INS RPSP EN 05 Fig 7 Platform Fig 8 Lateral Motorized Flap SML ...
Страница 12: ...11 Installation Manual RPSP INS RPSP EN 05 Fig 9 Frame crush proofing Fig 10 Anti impact ...
Страница 14: ...13 Installation Manual RPSP INS RPSP EN 05 Fig 12 Three phase electrical motor connections ...
Страница 57: ...56 Installation Manual RPSP INS RPSP EN 05 ...
Страница 58: ...57 Installation Manual RPSP INS RPSP EN 05 ...
Страница 60: ......