Reset Procedure
Reset Alarm:
The alarm will sound for 3 minutes. To reset, present a valid user card or enter
* (Master Code) #
via the
keypad
Reset to Factory Default:
To reset to factory default, power off, then press and hold the
*
button and power on, release it after you hear
two bleeps, the LED will turn orange. After 10 seconds, it will turn red and bleep once to confirm factory
default is successful
Note:
Reset to factory default, the user’s card/key fob information is still retained
Delete all users:
Delete all users of Zone 1:
* (Master Code) # 2 0000
#
Delete all users of Zone 2:
* (Master Code) # 9 0000
#