12
Keypad Lockout & Alarm Output options
.
If there are 10 invalid cards or 10 incorrect PIN numbers
in a 10 minute period either the keypad will lockout for 10 minutes or the alarm will operate for 10
minutes, depending on the option selected below
Normal status: No keypad
lockout or alarm
7 0 # (Factory default setting)
Keypad Lockout
7 1 #
Alarm Output
7 2 #
Alarm output time
To set the alarm output time
(1-3 minutes) Factory default
is 1 minute
8 1
~
3 #
Acoustic Signal
The acoustic signal can be set on or off. When on, the R3K will bleep when buttons are pressed; when off,
the R3K will be in silent mode
Normal status: On
8 6 # (Factory default setting)
Acoustic signal Off
8 7 #
Change Zone 2 to Door Bell
(When no need to operate a second door, Zone 2 can be set to operate the Door Bell. The wiring is
connecting the door bell to COM2 and NO2. Press #, the keypad will send the signal to the doorbell
Zone 2
8 8 # Factory default.
Doorbell
8 9 #
To remove the alarm
To reset the Door Forced Open
warning
Read valid card
or
Master Code #
To reset the Door Open Too
Long warning
Close the door
or
Read valid card
or
Master Code #